MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10875-007-9114-y

Медицинская библиотека · Journal of clinical immunology · 2007

Relationship between eosinophilia and levels of chemokines (CCL5 and CCL11) and IL-5 in bronchoalveolar lavage fluid of patients with mustard gas-induced pulmonary fibrosis.

Emad Ali, Emad Yasaman

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

Therefore, this study was designed to analyze the bronchoalveolar lavage (BAL) fluid concentrations of IL-5, RANTES (CCL5) and eotaxin (CCL11) and also to examine the relationship between the percentage and absolute number of the BAL eosinophils and these measured chemokines in patients with sulfur mustard (SM) gas-induced pulmonary fibrosis (PF).

PATIENTS: Fifteen veterans with mustard gas-induced PF and 14 normal veterans as control group.

INTERVENTION: Pulmonary function tests, tests for D(LCO), computed tomography scans of the chest, analyses of BAL fluids for RANTES (CCL5), eotaxin (CCL11), and IL-5 were performed in all cases.

RESULTS

Eosinophilic alveolitis was the predominant feature (p < 0.0001). There were significant differences in CCL5, CCL11, and IL-5 levels of BAL fluid between patients with PF and controls (p < 0.0001, p < 0.0001, and p = 0.001, respectively). The concentrations of CCL5 and CCL11 showed positive correlations with percentage (r = 0.57 and p = 0.03; r = 0.52 and p = 0.04, respectively) and absolute counts (r = 0.54 and p = 0.04, r = 0.53 and p = 0.04, respectively) of BAL eosinophils. There were significant positive correlations between the concentrations of IL-5 and the proportion and total cell number of eosinophils in BAL (r = 0.67 and p = 0.01; r = 0.59 and p = 0.02, respectively) too.

CONCLUSION

A significant correlation between BAL CCL5, CCL11, and IL-5 levels and eosinophils in patients with pulmonary fibrosis due to SM gas inhalation has been demonstrated, suggesting that these C-C chemokines and IL-5 contribute to the recruitment of eosinophils cells in the lung in these victims.

Для цитирования: Emad Ali, Emad Yasaman. Relationship between eosinophilia and levels of chemokines (CCL5 and CCL11) and IL-5 in bronchoalveolar lavage fluid of patients with mustard gas-induced pulmonary fibrosis.. Journal of clinical immunology. 2007. DOI: 10.1007/s10875-007-9114-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.