MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jchromb.2019.121805

Медицинская библиотека · Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2019

Validation of an improved liquid chromatography tandem mass spectrometry method for rapid and simultaneous analysis of plasma catecholamine and their metabolites.

Yu Songlin, Yin Yicong, Li Qianqian, Yu Jialei, Liu Wenjing, Wang Danchen, Cheng Qian, Xie Shaowei, Cheng Xinqi, Qiu Ling

СтатьяПеревод пока не подготовлен

Аннотация

Catecholamines [dopamine (DA), epinephrine (E), and norepinephrine (NE)] and their metabolites [metanephrine (MN), normetanephrine (NMN), and 3-methoxytyramine (3-MT)] are functionally important in humans. Their overexpression can indicate the presence of neuroendocrine tumors. Accurate and rapid quantitation of catecholamines and their metabolites may function in differential diagnosis of neuroendocrine tumors. Herein, we diluted 200 μL plasma using isotope labelled internal standards (IS), and extracted using solid phase extraction. The performance of isotope diluted liquid chromatography tandem mass spectrometry (ID-LC-MS/MS) was evaluated and applied to quantify the level of catecholamines and metabolites in clinical samples from 73 apparently healthy adults. The total analysis time of the ID-LC-MS/MS method was 4 min. The improved method was highly sensitive, with a limit of quantification (LOQ) for MN, NMN, 3-MT, and E of 1 pg/mL, a LOQ for DA of 5 pg/mL, and for NE of 10 pg/mL. After correction using IS, no significant matrix effects were observed. Good reproducibility was obtained, with total CVs of 3.2-13.1% (DA), 4.8-10.0% (E), 6.2-6.9% (NE), 3.8-7.9% (MN), 4.1-8.8% (NMN), 3.4-8.9% (3-MT). Recoveries were in the range of 91.1-109.7% for the six analytes. Also, the mean concentration of catecholamines were as follows: MN, 22.9 ± 7.2 pg/mL; NMN, 41.4 ± 17.2 pg/mL; 3-MT, 2.34 ± 2.01 pg/mL; DA, 10.2 ± 4.6 pg/mL; E, 29.3 ± 14.2 pg/mL and NE 427.0 ± 190.6 pg/mL. A reliable ID-LC-MS/MS method for the determination of catecholamines and their metabolites using small volumes of plasma was verified. This method is rapid, simple, and may serve as an essential diagnostic tool for neuroendocrine tumors in clinical practice.

Для цитирования: Yu Songlin, Yin Yicong, Li Qianqian, Yu Jialei, Liu Wenjing, Wang Danchen, Cheng Qian, Xie Shaowei, Cheng Xinqi, Qiu Ling. Validation of an improved liquid chromatography tandem mass spectrometry method for rapid and simultaneous analysis of plasma catecholamine and their metabolites.. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences. 2019. DOI: 10.1016/j.jchromb.2019.121805.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.