OBJECTIVE

To investigate the short-term effectiveness of femoral neck system (FNS) in the treatment of femoral neck fracture.

METHODS

The clinical data of 34 patients with femoral neck fracture admitted between January 2019 and April 2020 who met the selection criteria were retrospectively analyzed and divided into group A (19 patients were treated with conventional cannulated screw internal fixation) and group B (15 patients were treated with FNS internal fixation) according to the different methods of internal fixation. There was no significant difference between the two groups in general data such as gender, age, affected side, cause of injury, fracture type, and time from injury to operation ( P>0.05). The operation time, intraoperative blood loss, fluoroscopy frequency, and fracture healing time were recorded and compared between the two groups. X-ray film and CT examinations were performed postoperatively to evaluate fracture reduction and internal fixation, and the shortening of the femoral neck on the affected side was measured compared with that on the healthy side. The Harris score was used to evaluate hip function.

RESULTS

There was 1 unsatisfied reduction case in groups A and B respectively, the rest of the patients in both groups were obtained satisfied reduction. There was no significant difference in the quality of reduction between the two groups ( Z=-0.195, P=0.854). There was no significant difference in operation time between the two groups ( t=0.649, P=0.064). The intraoperative blood loss in group A was significantly less than that in group B, and the fluoroscopy frequency was significantly more than that in group B, with significant differences ( P<0.05). Except for 1 case in group A with screw out at 3 months after operation and no obvious callus formation, all fractures in the two groups reached clinical healing, and there was no significant difference in fracture healing time between the two groups ( t=-0.127, P=0.899). There was no necrosis of femoral head in the two groups. At last follow-up, there were 4 cases of femoral neck shortening in group A and 2 cases in group B. The hip function of both groups recovered well, and there was no significant difference in Harris score at last follow-up ( t=0.956, P=0.346).

CONCLUSION

The treatment of femoral neck fracture using FNS has less trauma. Compared with cannulated screw internal fixation, it can reduce the intraoperative fluoroscopy frequency and obtain satisfactory short-term effectiveness.

Для цитирования: Yang Yajun, Ma Tao, Zhang Xiaoyu, Luo Xiaojun, Fan Tao, Wang Yuhai. [Short-term effectiveness of femoral neck system in the treatment of femoral neck fracture].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2021. DOI: 10.7507/1002-1892.202012097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.