Accuracy in melanoma detection: a 10-year multicenter survey.

Argenziano Giuseppe, Cerroni Lorenzo, Zalaudek Iris, Staibano Stefania, Hofmann-Wellenhof Rainer, Arpaia Nicola, Bakos Renato Marchiori, Balme Brigitte, Bandic Jadran, Bandelloni Roberto, Brunasso Alexandra M G, Cabo Horacio, Calcara David A, Carlos-Ortega Blanca, Carvalho Ana Carolina, Casas Gabriel, Dong Huiting, Ferrara Gerardo, Filotico Raffaele, Gómez Guillermo, Halpern Allan, Ilardi Gennaro, Ishiko Akira, Kandiloglu Gulsen, Kawasaki Hiroshi, Kobayashi Ken, Koga Hiroshi, Kovalyshyn Ivanka, Langford David, Liu Xin, Marghoob Ashfaq A, Mascolo Massimo, Massone Cesare, Mazzoni Laura, Menzies Scott, Minagawa Akane, Nugnes Loredana, Ozdemir Fezal, Pellacani Giovanni, Seidenari Stefania, Siamas Katherine, Stanganelli Ignazio, Stoecker William V, Tanaka Masaru, Thomas Luc, Tschandl Philipp, Kittler Harald

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Early excision is the only strategy to reduce melanoma mortality, but unnecessary excision of benign lesions increases morbidity and healthcare costs.

OBJECTIVE

To assess accuracy in melanoma detection based on number-needed-to-excise (NNE) values over a 10-year period.

METHODS

Information was retrieved on all histopathologically confirmed cutaneous melanomas or melanocytic nevi that were excised between 1998 and 2007 at participating clinics. NNE values were calculated by dividing the total number of excised lesions by the number of melanomas. Analyses included changes in NNE over time, differences in NNE between specialized clinical settings (SCS) versus non-specialized clinical settings (NSCS), and patient factors influencing NNE.

RESULTS

The participating clinics contributed a total of 300,215 cases, including 17,172 melanomas and 283,043 melanocytic nevi. The overall NNE values achieved in SCS and NSCS in the 10-year period were 8.7 and 29.4, respectively. The NNE improved over time in SCS (from 12.8 to 6.8), but appeared unchanged in NSCS. Most of the effect on NNE in SCS was due to a greater number of excised melanomas. Higher NNE values were observed in patients younger than 40 years and for lesions located on the trunk.

LIMITATIONS: No data concerning the use of dermatoscopy and digital monitoring procedures were collected from the participating centers.

CONCLUSION

Over the 10-year study period, accuracy in melanoma detection improved only in specialized clinics maybe because of a larger use of new diagnostic techniques such as dermatoscopy.

Для цитирования: Argenziano Giuseppe, Cerroni Lorenzo, Zalaudek Iris, Staibano Stefania, Hofmann-Wellenhof Rainer, Arpaia Nicola, Bakos Renato Marchiori, Balme Brigitte, Bandic Jadran, Bandelloni Roberto, Brunasso Alexandra M G, Cabo Horacio, Calcara David A, Carlos-Ortega Blanca, Carvalho Ana Carolina, Casas Gabriel, Dong Huiting, Ferrara Gerardo, Filotico Raffaele, Gómez Guillermo, Halpern Allan, Ilardi Gennaro, Ishiko Akira, Kandiloglu Gulsen, Kawasaki Hiroshi, Kobayashi Ken, Koga Hiroshi, Kovalyshyn Ivanka, Langford David, Liu Xin, Marghoob Ashfaq A, Mascolo Massimo, Massone Cesare, Mazzoni Laura, Menzies Scott, Minagawa Akane, Nugnes Loredana, Ozdemir Fezal, Pellacani Giovanni, Seidenari Stefania, Siamas Katherine, Stanganelli Ignazio, Stoecker William V, Tanaka Masaru, Thomas Luc, Tschandl Philipp, Kittler Harald. Accuracy in melanoma detection: a 10-year multicenter survey.. Journal of the American Academy of Dermatology. 2011. DOI: 10.1016/j.jaad.2011.07.019.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.