MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12968-022-00859-z

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2022

Cardiovascular magnetic resonance native T1 mapping in Anderson-Fabry disease: a systematic review and meta-analysis.

Ponsiglione Andrea, Gambardella Michele, Green Roberta, Cantoni Valeria, Nappi Carmela, Ascione Raffaele, De Giorgi Marco, Cuocolo Renato, Pisani Antonio, Petretta Mario, Cuocolo Alberto, Imbriaco Massimo

СтатьяМетаанализСистематический обзорПеревод пока не подготовлен

Аннотация

BACKGROUND

T1 mapping is an established cardiovascular magnetic resonance (CMR) technique that can characterize myocardial tissue. We aimed to determine the weighted mean native T1 values of Anderson-Fabry disease (AFD) patients and the standardized mean differences (SMD) as compared to healthy control subjects.

METHODS

A comprehensive literature search of the PubMed, Scopus and Web of Science databases was conducted according to the PRISMA statement to retrieve original studies reporting myocardial native T1 values in AFD patients and healthy controls. A random effects model was used to calculate SMD, and meta-regression analysis was conducted to explore heterogeneity sources. Subgroup analysis was also performed according to scanner field strength and sequence type.

RESULTS

From a total of 151 items, 14 articles were included in the final analysis accounting for a total population of 982 subjects. Overall, the weighted mean native T1 values was 984 ± 47 ms in AFD patients and 1016 ± 26 ms in controls (P < 0.0001) with a pooled SMD of - 2.38. In AFD patients there was an inverse correlation between native T1 values and male gender (P = 0.002) and left ventricular hypertrophy (LVH) (P < 0.001). Subgroup analyses confirmed lower T1 values in AFD patients compared to controls with a pooled SMD of -  2.54,  -  2.28, -   2.46 for studies performed on 1.5T with modified Look-Locker inversion recovery (MOLLI), shortened MOLLI and saturation-recovery single-shot acquisition, respectively and of -  2.41 for studies conducted on 3T.

CONCLUSIONS

Our findings confirm a reduction of native T1 values in AFD patients compared to healthy controls and point out that the degree of T1 shortening in AFD is influenced by gender and LVH. Although T1 mapping is useful in proving cardiac involvement in AFD patients, there is need to standardize shreshold values according to imaging equipment and protocols.

Для цитирования: Ponsiglione Andrea, Gambardella Michele, Green Roberta, Cantoni Valeria, Nappi Carmela, Ascione Raffaele, De Giorgi Marco, Cuocolo Renato, Pisani Antonio, Petretta Mario, Cuocolo Alberto, Imbriaco Massimo. Cardiovascular magnetic resonance native T1 mapping in Anderson-Fabry disease: a systematic review and meta-analysis.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2022. DOI: 10.1186/s12968-022-00859-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.