MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/jnis-2023-020602

Медицинская библиотека · Journal of neurointerventional surgery · 2024

Impact on collateral flow of devices used for endovascular treatment of stroke: an in-vitro flow model.

Requena Manuel, Li Jiahui, Tiberi Riccardo, Canals Pere, Olive Gadea Marta, de Dios Lascuevas Marta, Jabłońska Magda, Cendrero Judith, Garcia-Tornel Alvaro, Tomasello Alejandro, Ribo Marc

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Collateral blood supply of distal vessels has been linked to clinical outcome, infarct volume and recanalization rates in patients with large vessel occlusion. Our study aimed to explore the effects of catheterization during mechanical thrombectomy in collaterals.

METHODS

We quantified the flow diversion effect secondary to arterial occlusions in an in vitro model which was connected in a flow-loop setup with a saline reservoir and a pump supplying pulsatile flow. Clot analogs were embolized to the middle cerebral artery (MCA) M1 or M2 segments. We used the same model with a clamped anterior communicating artery (AComA) to simulate its absence. An ultrasound flow sensor was placed at the vessel of interest. Flow rates and pressures were evaluated according to the following catheter locations: baseline (1) before and (2) after the occlusion; (3) 8F guiding catheter at the internal carotid artery (ICA) bulb; (4) at the cavernous segment; (5) at the cavernous segment a 0.071" distal access catheter at proximal M1; (6) 8F balloon guide catheter inflated.

RESULTS

Collateral blood flow measured at distal anterior cerebral artery (ACA) (M1-MCA occlusion) and M2-MCA (M2-MCA occlusion) was progressively reduced as catheters were advanced through the ICA and MCA. In the lacking AComA model, the flow was further diminished as compared with the model with a patent AComA.

CONCLUSION

Our in vitro study showed a progressive reduction of collateral blood flow due to the advance of catheters during mechanical thrombectomy.

Для цитирования: Requena Manuel, Li Jiahui, Tiberi Riccardo, Canals Pere, Olive Gadea Marta, de Dios Lascuevas Marta, Jabłońska Magda, Cendrero Judith, Garcia-Tornel Alvaro, Tomasello Alejandro, Ribo Marc. Impact on collateral flow of devices used for endovascular treatment of stroke: an in-vitro flow model.. Journal of neurointerventional surgery. 2024. DOI: 10.1136/jnis-2023-020602.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.