MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/ana.26748

Медицинская библиотека · Annals of neurology · 2023

Comparison of CT Perfusion Software Packages for Thrombectomy Eligibility.

Pisani Leonardo, Haussen Diogo C, Mohammaden Mahmoud, Perry da Camara Catarina, Jillella Dinesh V, Rodrigues Gabriel M, Bouslama Mehdi, Al-Bayati Alhamza, Prater Adam, Liberato Bernardo, Frankel Michael R, Nogueira Raul G

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Computed tomography perfusion (CTP) has played an important role in patient selection for mechanical thrombectomy (MT) in acute ischemic stroke. We aimed to investigate the agreement between perfusion parametric maps of 3 software packages - RAPID (RapidAI-IschemaView), Viz CTP(Viz.ai), and e-CTP(Brainomix) - in estimating baseline ischemic core volumes of near completely/completely reperfused patients.

METHODS

We retrospectively reviewed a prospectively maintained MT database to identify patients with anterior circulation large vessel occlusion strokes (LVOS) involving the internal carotid artery or middle cerebral artery M1-segment and interpretable CTP maps treated during September 2018 to November 2019. A subset of patients with near-complete/complete reperfusion (expanded thrombolysis in cerebral infarction [eTICI] 2c-3) was used to compare the pre-procedural prediction of final infarct volumes.

RESULTS

In this analysis of 242 patients with LVOS, RAPID and Viz CTP relative cerebral blood flow (rCBF) < 30% values had substantial agreement (ρ = 0.767 [95% confidence interval [CI] = 0.71-0.81]) as well as for RAPID and e-CTP (ρ = 0.668 [95% CI = 0.61-0.71]). Excellent agreement was seen for time to maximum of the residue function (Tmax ) > 6 seconds between RAPID and Viz CTP (ρ = 0.811 [95% CI = 0.76-0.84]) and substantial for RAPID and e-CTP (ρ = 0.749 [95% CI = 0.69-0.79]). Final infarct volume (FIV) prediction (n = 136) was substantial in all 3 packages (RAPID ρ = 0.744; Viz CTP ρ = 0.711; and e-CTP ρ = 0.600).

CONCLUSION

Perfusion parametric maps of the RAPID, Viz CTP, and e-CTP software have substantial agreement in predicting final infarct volume in near-completely/completely reperfused patients. ANN NEUROL 2023;94:848-855.

Для цитирования: Pisani Leonardo, Haussen Diogo C, Mohammaden Mahmoud, Perry da Camara Catarina, Jillella Dinesh V, Rodrigues Gabriel M, Bouslama Mehdi, Al-Bayati Alhamza, Prater Adam, Liberato Bernardo, Frankel Michael R, Nogueira Raul G. Comparison of CT Perfusion Software Packages for Thrombectomy Eligibility.. Annals of neurology. 2023. DOI: 10.1002/ana.26748.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.