MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/apt.17607

Медицинская библиотека · Alimentary pharmacology & therapeutics · 2023

Accuracy of ultrasound, bioelectrical impedance analysis and anthropometry as point-of-care measurements of skeletal muscle mass in patients with inflammatory bowel disease.

Nguyen Anke L, Burns Megan, Herath Madhuni, Lambell Kate, Holt Darcy, Fitzpatrick Jessica, Milat Frances, Ebeling Peter R, Gibson Peter R, Moore Gregory T

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

Disturbance of skeletal muscle mass has clinically important implications in patients with inflammatory bowel disease (IBD), but accurate quantification requires radiation-intense techniques.

AIMS: We aimed to compare point-of-care muscle assessments and their change with therapy with those using reference-standard whole-body dual energy X-ray absorptiometry (DXA).

METHODS

Adult patients with IBD and healthy controls underwent prospective assessment of muscularity by ultrasound of the dominant arm and both thighs, bioelectrical impedance analysis (BIA), anthropometric measurements, and DXA. Patients with active IBD were assessed again ≥13 weeks after initiating biologic induction therapy.

RESULTS

In 54 patients with IBD and 30 controls, all muscle assessments correlated significantly with DXA-derived skeletal muscle index (SMI). In IBD, ultrasound of the arm and legs had the best agreement with DXA-derived SMI (mean difference 0 kg/m2 , 95% limits of agreement -1.3 to 1.3), while BIA overestimated DXA-derived SMI by 1.07 (-0.16 to +2.30) kg/m2 . In 17 patients who underwent biologic therapy, the percentage change in DXA-derived SMI correlated significantly with the percentage change in all other muscle assessment techniques. Responders (n = 9) increased SMI from baseline to follow-up when derived from DXA (mean 7.8-8.5 kg/m2 , p = 0.004), ultrasound of the arm and legs (300-343 cm2 , p = 0.021) and BIA (9.2-9.6 kg/m2 , p = 0.011).

CONCLUSIONS

Ultrasound of the arm and legs out-performed other point-of-care methods in its accuracy of measuring muscle mass. All methods, except mid-arm circumference, were responsive to therapy-induced change. Ultrasound is the preferred non-invasive test for measuring muscle mass in patients with IBD.

Для цитирования: Nguyen Anke L, Burns Megan, Herath Madhuni, Lambell Kate, Holt Darcy, Fitzpatrick Jessica, Milat Frances, Ebeling Peter R, Gibson Peter R, Moore Gregory T. Accuracy of ultrasound, bioelectrical impedance analysis and anthropometry as point-of-care measurements of skeletal muscle mass in patients with inflammatory bowel disease.. Alimentary pharmacology & therapeutics. 2023. DOI: 10.1111/apt.17607.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.