DOI 10.1016/j.radonc.2008.09.022
Dosimetric comparison of three different treatment techniques in extensive scalp lesion irradiation.
Аннотация
BACKGROUND AND PURPOSE: This study compared lateral photon/electron plan (3DCRT), intensity modulated radiation therapy (IMRT) plan, and high dose rate (HDR) brachytherapy plan for total scalp irradiation.
MATERIALS AND
METHODS
The techniques were planned on a patient with squamous cell carcinoma of the scalp for a prescribed dose of 60 Gy. Conformity indexes and dose volume histograms were used for the comparison.
RESULTS
Clinical target volume coverage factors for 3DCRT, IMRT, and HDR were 0.976, 0.998, and 0.967, and Conformation Numbers were 0.532, 0.713, and 0.761, respectively. The dose gradient across the target was 59-136%, 91-129%, and 58-242% for 3DCRT, IMRT, and HDR techniques, respectively. The 3DCRT and IMRT techniques produced low optical structure doses. 3DCRT produced hotspots in the brain, while IMRT produced brain sparing. HDR produced the highest integral doses to the brain and optical structures.
CONCLUSIONS
IMRT provided the best target dose homogeneity and coverage, and delivered clinically acceptable doses to normal structures. HDR produced the most conformal plan, but the total dose delivered is limited by doses to the brain and eyes. HDR is a clinically feasible alternative for less extensive lesions, lower prescription doses, and for patients who cannot lie on the treatment table.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.