MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10554-025-03465-z

Медицинская библиотека · The international journal of cardiovascular imaging · 2025

Left ventricular ejection fraction evaluation by 99mTc-DPD cardiac gated SPECT in patients with ATTR amyloidosis: feasibility and limitations.

Dramé Boubacar, Martz Maximilien, El Ghannudi Soraya, Hubele Fabrice, Hien Mwinbele Stéphane, Bessac Darejan Mamulashvili, Zeyons Floriane, Hunolstein Jean-Jacques Von, Bathily El Hadji Amadou Lamine, Mertz Luc, Blondet Cyrille, Schindler Thomas Helmut, Imperiale Alessio

СтатьяСравнительное исследованиеПеревод пока не подготовлен

Аннотация

Cardiac function assessment using 99mTc-DPD ECG-gated SPECT (G-SPECT) in ATTR amyloidosis is underexplored. This study evaluates left ventricular ejection fraction (LVEF) and left ventricular end-diastolic volume (LVEDV) with G-SPECT, comparing results to transthoracic echocardiogram (TTE) and cardiac magnetic resonance imaging (CMR). A regression model obtained comparing G-SPECT and CMR was used to independently predict CMR LVEF from G-SPECT. In this retrospective study, 38 patients with cardiac ATTR amyloidosis (Perugini 2-3) underwent TTE, CMR, and G-SPECT within six months, excluding acute cardiac events or therapeutic changes. G-SPECT were evaluated using QPS-QGS software. A wall-model of polar map presentation was obtained from LV short-axis slices. In the first 30 consecutive patients, mean LVEF was 52.5%±11.3% by TTE, 57.9%±12.4% by CMR, and lower by G-SPECT (42.7%±10.1%, p < 0.001). LVEF from G-SPECT correlated significantly with CMR (r = 0.71, p < 0.001). The regression formula predicting CMR LVEF was: LVEFCMR=0.875 x LVEFGSPECT + 20.612. Mean LVEDV was 74.4 ± 21.0 ml/m² by CMR and 61.4 ± 22.9 ml/m² by G-SPECT (p < 0.001), with strong correlation (r = 0.76, p < 0.001). In the last 8 patients, predicted CMR LVEF was comparable to measured CMR LVEF (p = 0.87), with significant correlation (r = 0.73, p = 0.039). This study reveals that 99mTc-DPD G-SPECT underestimates LVEF and LVEDV compared to CMR, though a consistent correlation was observed between the two modalities. As one of the first structured attempts to explore G-SPECT functional parameters in this setting, our work should be considered a proof of concept, highlighting both the feasibility and the current limitations of this approach. Further studies are needed to refine its accuracy and clarify its place within multimodal clinical imaging strategies.

Для цитирования: Dramé Boubacar, Martz Maximilien, El Ghannudi Soraya, Hubele Fabrice, Hien Mwinbele Stéphane, Bessac Darejan Mamulashvili, Zeyons Floriane, Hunolstein Jean-Jacques Von, Bathily El Hadji Amadou Lamine, Mertz Luc, Blondet Cyrille, Schindler Thomas Helmut, Imperiale Alessio. Left ventricular ejection fraction evaluation by 99mTc-DPD cardiac gated SPECT in patients with ATTR amyloidosis: feasibility and limitations.. The international journal of cardiovascular imaging. 2025. DOI: 10.1007/s10554-025-03465-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.