MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ophtha.2008.09.001

Медицинская библиотека · Ophthalmology · 2008

Intraocular pressure and corneal biomechanical properties in patients with myotonic dystrophy.

Rosa Nicola, Lanza Michele, Borrelli Maria, Palladino Alberto, Di Gregorio M Grazia, Politano Luisa

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare intraocular pressure (IOP) between patients with myotonic dystrophy (DM1) and normal subjects, taking into account corneal characteristics. To determine whether lower IOP measurements in patients with DM1 are due to thinner corneas.

DESIGN

Comparative case series.

PARTICIPANTS

Fifty-three eyes of patients with DM1 and 53 eyes of normal age- and sex-matched subjects.

METHODS

Corneal biomechanical properties and corneal compensated intraocular pressure (IOPcc) measured with the Ocular Response Analyzer (Reichert Inc., Depew, NY), central corneal thickness measured with the Oculus Pentacam (Oculus, Wetzlar, Germany), and IOP were evaluated in patients with DM1 and compared with age- and sex-matched healthy subjects.

MAIN OUTCOME MEASUREMENTS: Goldmann applanation tonometry, central corneal thickness, corneal hysteresis (CH), corneal resistance factor (CRF), and IOPcc.

RESULTS

Compared with the healthy subjects, patients with DM1 showed lower IOP (12.4+/-3.6 mm Hg vs. 14.9+/-3.4 mmHg) (P<0.01) and IOPcc (12.7+/-4.5 vs. 15.9+/-3.5) (P<0.01), and thicker cornea (575.9+/-35.02 mum vs. 556.3+/-33.2 microm) (P<0.01), but no significant changes in CH (P = 0.03) and CRF (P = 0.37).

CONCLUSIONS

Lower IOP in patients with DM1 is not related to differences in central corneal thickness or corneal biomechanical properties.

FINANCIAL DISCLOSURE(S): The author(s) have no proprietary or commercial interest in any materials discussed in this article.

Для цитирования: Rosa Nicola, Lanza Michele, Borrelli Maria, Palladino Alberto, Di Gregorio M Grazia, Politano Luisa. Intraocular pressure and corneal biomechanical properties in patients with myotonic dystrophy.. Ophthalmology. 2008. DOI: 10.1016/j.ophtha.2008.09.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.