Hsu Jason, Chen Eric, Gupta Omesh, Fineman Mitchell S, Garg Sunir J, Regillo Carl D

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To compare intraocular pressure (IOP) and rates of postoperative hypotony with 25-gauge pars plana vitrectomy (PPV) without tamponade using oblique versus direct cannula insertions.

METHODS

A prospective consecutive series of eyes that underwent 25-gauge PPV without tamponade using an oblique cannula insertion technique was compared with a historical consecutive series of eyes that underwent 25-gauge PPV without tamponade using direct cannula insertions. IOP was recorded before surgery, on postoperative day 1, and on postoperative week 1.

RESULTS

Ninety-five eyes had 25-gauge PPV without tamponade, 55 with oblique cannula insertions and 40 with direct insertions. With oblique insertions, there was no statistically significant difference between mean IOPs measured before surgery, on postoperative day 1, and on postoperative week 1. Only 1 (1.8%) of the 55 eyes had hypotony (IOP, <or=5 mmHg) on postoperative day 1. With direct insertions, mean postoperative day 1 IOP was significantly lower than mean preoperative IOP (P = 0.009). Mean preoperative and postoperative week 1 IOPs were similar. Four (10%) of 40 eyes had hypotony on postoperative day 1.

CONCLUSIONS

Oblique cannula insertions may be superior to direct cannula insertions for lowering rates of absolute and relative postoperative day 1 hypotony in 25-gauge PPV without tamponade.

Для цитирования: Hsu Jason, Chen Eric, Gupta Omesh, Fineman Mitchell S, Garg Sunir J, Regillo Carl D. Hypotony after 25-gauge vitrectomy using oblique versus direct cannula insertions in fluid-filled eyes.. Retina (Philadelphia, Pa.). 2008. DOI: 10.1097/iae.0b013e31816c6855.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.