Early post-phacoemulsification hypotony as a risk factor for intraocular contamination: in vivo model.

Chawdhary Satish, Anand Aashish

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To observe cataract wound dynamics and determine the risk for intraocular contamination under induced conditions of early postoperative hypotony after anterior chamber decompression for high intraocular pressure (IOP) spikes after uneventful phacoemulsification surgery.

SETTING

Department of Ophthalmology, Queen's Hospital, Burton-on-Trent, United Kingdom.

METHODS

In a prospective case series, 30 patients were treated with anterior chamber decompression for elevated IOP (>35 mm Hg) 1 to 2 hours after uneventful phacoemulsification through clear corneal temporal incisions. A drop of 2% fluorescein was instilled in the conjunctival sac before aqueous release to study the ocular fluid movements during and after the decompression procedure. The patterns of fluorescein movement were observed and photographed under cobalt blue light.

RESULTS

Fluorescein staining of the entire corneal tunnel was observed in all 30 eyes after decompression. An immediate fluorescein flare was observed in the anterior chamber after aqueous release in 24 eyes (80%) (P<.001). Observations over several seconds after decompression found a frank influx of fluorescein-stained fluid into the anterior chamber in 12 eyes (40%) (P<.001), giving rise to an "inverse Seidel's test." An intermittent ingress of fluorescein-stained fluid continued for several minutes after the procedure in 6 eyes (20%) (P<.05).

CONCLUSIONS

An incompetence of clear corneal cataract wound with intraocular contamination was observed during the period of induced hypotony after anterior chamber decompression in the early post-phacoemulsification period.

Для цитирования: Chawdhary Satish, Anand Aashish. Early post-phacoemulsification hypotony as a risk factor for intraocular contamination: in vivo model.. Journal of cataract and refractive surgery. 2006. DOI: 10.1016/j.jcrs.2006.01.020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.