Bhende M, Lekha T, Vijaya L, Gopal L, Sharma T, Parikh S
Аннотация
PURPOSE: To report the role of Ultrasound Biomicroscopy (UBM) as a tool in the diagnosis and management of cyclodialysis clefts.
METHODS: Six eyes of 6 patients with hypotony and suspected or diagnosed cyclodialysis clefts underwent UBM evaluation. Post-treatment UBM was performed in four eyes to assess the effect of the treatment.
RESULTS: Cyclodialysis clefts were accurately diagnosed and delineated in 6 eyes by UBM. Complete closure was documented after treatment in 3 eyes, and a residual cleft in one eye. These findings were compared to gonioscopic findings.
CONCLUSIONS: UBM is a safe, accurate and noninvasive diagnostic tool in the diagnosis of cyclodialysis clefts and is of particular use when other conventional methods of diagnosis are inconclusive.