MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10792-003-7609-y

Медицинская библиотека · International ophthalmology · 2004

Use of silicone oil in the management of complex retinal detachment--an Indian experience.

Silicone Oil Study Group of Sankara Nethralaya

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND AND

OBJECTIVE

In the management of complicated retinal detachments (RD), temporary silicone oil tamponade has been increasingly used. This study reports results and complications of temporary silicone oil tamponade that was used to treat complicated RD associated with multiple etiologies.

MATERIALS AND

METHODS

Between 1988 and 1998, a total of four thousand four hundred and eighty-eight (4488) eyes underwent vitreous surgery and silicone oil tamponade. Outcome measures were: anatomic and functional success and postoperative complications such as cataract, corneal changes, hypotony, and glaucoma. An eye was considered an anatomic success if there was a complete retinal reattachment or macular attachment. Functional success was defined as attainment of visual acuity of 5/200 or better. Multiple logistic regression analysis was performed to elucidate the relationship between various pre- and postoperative variables and outcome measures. Mean follow-up was 17 months, and median, 8 months.

RESULTS

Overall, anatomic success was achieved in 73% of the eyes, and functional success, in 47%. After removal of silicone oil, recurrence of retinal detachment was observed in 9% of the eyes; a high percentage (70%) of eyes attained functional success. Postoperative cataract was observed in 65.3%, abnormal corneas in 21.3%, hypotony in 16.9%, and glaucoma in 16.4% of the eyes.

CONCLUSIONS

Despite the onset of complications related to silicone oil usage, a high rate of reattachment of the retina was observed following vitrectomy and silicone oil tamponade in the management of complex RD associated with multiple etiologies.

Для цитирования: Silicone Oil Study Group of Sankara Nethralaya. Use of silicone oil in the management of complex retinal detachment--an Indian experience.. International ophthalmology. 2004. DOI: 10.1007/s10792-003-7609-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.