MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1183/09031936.00077706

Медицинская библиотека · The European respiratory journal · 2006

Ultrasound-assisted transthoracic biopsy: fine-needle aspiration or cutting-needle biopsy?

Diacon A H, Theron J, Schubert P, Brundyn K, Louw M, Wright C A, Bolliger C T

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

The present study compared the diagnostic yield of ultrasound-assisted cutting-needle biopsy (CNB) and fine-needle aspiration biopsy (FNAB) in chest lesions. A physician performed ultrasound and FNAB with a 22-G spinal needle in all patients, directly followed by a 14-G CNB in patients without contraindication. A total of 155 consecutive lesions arising from the lung (74%), pleura (12%), mediastinum (11%) or chest wall (3%) in patients with a final diagnosis of lung carcinoma (74%), other malignant tumours (12%), non-neoplastic disease (9%) or unknown (5%) were prospectively included. The overall diagnostic yield was 87%. Combined specimens were obtained in 123 lesions (79%). In these, yields of FNAB, CNB and both methods combined were 82, 76 and 89%, respectively. FNAB was significantly better than CNB in lung carcinoma (95 versus 81%) but CNB was superior in noncarcinomatous tumours and in benign lesions. On-site cytology was 90% sensitive and 100% specific for predicting a positive FNAB. One patient required drainage for pneumothorax (0.6%). Ultrasound-assisted fine-needle aspiration biopsy performed by chest physicians is an accurate and safe initial diagnostic procedure in patients with a high clinical probability of lung carcinoma. All other patients should undergo concurrent fine-needle aspiration biopsy and cutting-needle biopsy.

Для цитирования: Diacon A H, Theron J, Schubert P, Brundyn K, Louw M, Wright C A, Bolliger C T. Ultrasound-assisted transthoracic biopsy: fine-needle aspiration or cutting-needle biopsy?. The European respiratory journal. 2006. DOI: 10.1183/09031936.00077706.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.