BACKGROUND

Despite the existence of several Randomized Controlled Trials (RCTs) investigating Low-Dose Computed Tomography (LDCT) as a guide in lung biopsies, conclusive findings remain elusive. To address this contention, we conducted a systematic review and meta-analysis to evaluate the efficacy and safety of LDCT-guided lung biopsies.

METHODS

A comprehensive search across major databases identified RCTs comparing the effectiveness of LDCT-guided with Standard-Dose Computed Tomography (SDCT)-guided lung biopsies. Subsequently, we utilized a random-effects model meta-analysis to assess diagnostic accuracy, radiation dose, operation duration, and clinical complications associated with these procedures.

RESULTS

Out of 292 scrutinized studies, six RCTs representing 922 patients were included in the final analysis. Results indicated the differences between the LDCT and SDCT groups were not different with statistical significance in terms of diagnostic accuracy rates (Intent-to-Treat (ITT) populations: Relative Risk (RR) 1.01, 95% Confidence interval [CI] 0.97-1.06, p = 0.61; Per-Protocol (PP) populations: RR 1.01, 95% CI 0.98-1.04, p = 0.46), incidence of pneumothorax (RR 1.00, 95% CI 0.75-1.35, p = 0.98), incidence of hemoptysis (RR 0.95, 95% CI 0.63-1.43, p = 0.80), and operation duration (minutes) (Mean Differences [MD] -0.34, 95% CI -1.67-0.99, p = 0.61). Notably, LDCT group demonstrated a lower radiation dose (mGy·cm) with statistical significance (MD -188.62, 95% CI -273.90 to -103.34, p < 0.0001).

CONCLUSIONS

The use of LDCT in lung biopsy procedures demonstrated equivalent efficacy and safety to standard methods while notably reducing patient radiation exposure.

Для цитирования: Li Teng, Xu Guanghui, Li Wenjun, Liu Yun. A systematic review and meta-analysis of randomized controlled trials comparing low-dose versus standard-dose computed tomography-guided lung biopsy.. Journal of cardiothoracic surgery. 2024. DOI: 10.1186/s13019-024-02792-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.