MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/crd.0000000000000660

Медицинская библиотека · Cardiology in review · 2024

Transvenous Compared With Leadless Pacemakers: A meta-analysis comparing TP versus LP.

Habboush Shady, Elmoursi Ahmed, Gadelmawla Ahmed F, Masoud Amr T, Khalil Mohamed, Sheashaa Hesham, Merza Nooraldin, Massoud Ahmed T

СтатьяМетаанализСравнительное исследованиеОбзорПеревод пока не подготовлен

Аннотация

This study aims to compare the effectiveness of leadless pacemakers (LPs) and transvenous pacemakers and to examine the safety of both methods. We included patients undergoing single-chamber pacemaker implantation, either LP or TVP. Our outcomes were successful implantation rate, major complication, vascular injury, tamponade, and pneumothorax. We performed a double-arm analysis comparing LP versus TVP, with risk ratio (RR) and 95% confidence interval. A total of 10 studies were included in this meta-analysis. Regarding efficacy endpoints, RR revealed no significant difference between the LP and transvenous pacemaker groups in terms of successful rate of implantation (RR = 1.00; P = 0.77). Regarding safety outcomes, LP experienced lower incidence of major complications (RR = 0.47; P = 0.01), infection (RR = 0.24; P = 0.001), and tamponade (RR = 0.36; P = 0.01). There was no significant difference between both groups regarding pneumothorax (RR = 0.35; P = 0.22) and vascular injury (RR = 1.55; P = 0.25). The study findings suggest that both LPs and TVPs have similar effectiveness. Moreover, the incidences of pneumothorax, vascular injuries, and major complications were found to be comparable between the 2 methods. However, LPs were found to have lower rates of infection and tamponade.

Для цитирования: Habboush Shady, Elmoursi Ahmed, Gadelmawla Ahmed F, Masoud Amr T, Khalil Mohamed, Sheashaa Hesham, Merza Nooraldin, Massoud Ahmed T. Transvenous Compared With Leadless Pacemakers: A meta-analysis comparing TP versus LP.. Cardiology in review. 2024. DOI: 10.1097/crd.0000000000000660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.