m+Medelevator.RU
← Поиск публикаций
Viruses · 2023

Rapid Detection of SARS-CoV-2 RNA Using Reverse Transcription Recombinase Polymerase Amplification (RT-RPA) with Lateral Flow for N-Protein Gene and Variant-Specific Deletion-Insertion Mutation in S-Protein Gene.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Malaga Jose L, Pajuelo Monica J, Okamoto Michiko, Tsinda Emmanuel Kagning, Otani Kanako, Tsukayama Pablo, Mascaro Lucero, Cuicapuza Diego, Katsumi Masamichi, Kawamura Kazuhisa, Nishimura Hidekazu, Sakagami Akie, Ueki Yo, Omiya Suguru, Okamoto Satoshi, Nakayama Asami, Fujimaki Shin-Ichi, Yu Chuyao, Azam Sikandar, Kodama Eiichi, Dapat Clyde, Oshitani Hitoshi, Saito Mayuko

Аннотация

Rapid molecular testing for severe acute respiratory coronavirus 2 (SARS-CoV-2) variants may contribute to the development of public health measures, particularly in resource-limited areas. Reverse transcription recombinase polymerase amplification using a lateral flow assay (RT-RPA-LF) allows rapid RNA detection without thermal cyclers. In this study, we developed two assays to detect SARS-CoV-2 nucleocapsid (N) gene and Omicron BA.1 spike (S) gene-specific deletion-insertion mutations (del211/ins214). Both tests had a detection limit of 10 copies/µL in vitro and the detection time was approximately 35 min from incubation to detection. The sensitivities of SARS-CoV-2 (N) RT-RPA-LF by viral load categories were 100% for clinical samples with high (>9015.7 copies/µL, cycle quantification (Cq): < 25) and moderate (385.5-9015.7 copies/µL, Cq: 25-29.9) viral load, 83.3% for low (16.5-385.5 copies/µL, Cq: 30-34.9), and 14.3% for very low (<16.5 copies/µL, Cq: 35-40). The sensitivities of the Omicron BA.1 (S) RT-RPA-LF were 94.9%, 78%, 23.8%, and 0%, respectively, and the specificity against non-BA.1 SARS-CoV-2-positive samples was 96%. The assays seemed more sensitive than rapid antigen detection in moderate viral load samples. Although implementation in resource-limited settings requires additional improvements, deletion-insertion mutations were successfully detected by the RT-RPA-LF technique.

Предметные рубрики MeSH