MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1364/ol.612420

Медицинская библиотека · Optics letters · 2026

Absorbing-molecule-induced optical clearing enhances Cerenkov luminescence imaging of radiopharmaceutical distribution.

Zhuang Haichao, Geng Changran, Xie Fei, Qian Gensheng, Ren Yuan, Yang Jinkai, Tang Xiaobin

СтатьяПеревод пока не подготовлен

Аннотация

Cerenkov luminescence imaging (CLI) enables noninvasive and real-time tracking of the in vivo distribution of radiopharmaceuticals by detecting Cerenkov optical signals generated during radionuclide decay. However, biological tissues exhibit strong scattering and absorption in the visible spectrum, which not only markedly attenuate Cerenkov signals but also cause discrepancies between the detected optical signals and the actual in vivo distribution of radiopharmaceuticals, thereby limiting the imaging accuracy of CLI. Here, we demonstrate that skin optical clearing alleviates this limitation and enhances the spatial fidelity of CLI images. An absorbing-molecule-based optical clearing treatment markedly decreased the tissue reduced scattering coefficient, increasing visible light transmittance through mouse skin by more than 50-fold (from 0.47% to 24.55%) while reducing skin reflectance by approximately 68.8%. Using 68Ga as the radiotracer, the agreement between CLI and positron emission tomography (PET) was substantially improved, with the Pearson correlation coefficient increasing from 0.55 to 0.78 and the Spearman correlation coefficient from 0.63 to 0.82. After a 15-day recovery period following optical clearing treatment, the treated mouse showed hair regrowth and signs of skin recovery. These results support the potential of optical clearing as a simple and effective strategy for improving the spatial correspondence of CLI with radiopharmaceutical distribution.

Для цитирования: Zhuang Haichao, Geng Changran, Xie Fei, Qian Gensheng, Ren Yuan, Yang Jinkai, Tang Xiaobin. Absorbing-molecule-induced optical clearing enhances Cerenkov luminescence imaging of radiopharmaceutical distribution.. Optics letters. 2026. DOI: 10.1364/ol.612420.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.