Role of CT perfusion imaging in patients with variously differentiated gastric adenocarcinoma.
Аннотация
PURPOSE: To explore the characteristics of variously differentiated gastric cancers on computed tomography (CT) perfusion imaging, including specific perfusion parameter values, and potential clinical applications in the prognosis assessment of gastric cancer.
MATERIALS AND
METHODS
Fifty patients with gastric cancer confirmed by gastroscope pathology were studied prospectively using CT perfusion imaging examinations on a 64-slice spiral CT scanner. The acquired volume data were used for calculations, mapping, and analysis by using an abdominal tumor perfusion protocol (deconvolution method) in the CT perfusion software package to measure 4 parameters: blood flow (BF), blood volume (BV), mean transit time (MTT), and the permeability surface (PS) area product. The different differentiated Gastric cancers with CT perfusion values were divided into 3 groups: well-differentiated, moderately differentiated and poorly differentiated gastric adenocarcinoma, and compared statistically with one another by statistical software.
RESULTS
The mean perfusion values of 10 patients with well-differentiated gastric adenocarcinoma were as follows: BF, 75.28 ± 6.81 mL/100 g/min; BV, 9.01 ± 0.94 mL/100 g; MTT, 9.89 ± 1.65 s; and PS, 10.05 ± 0.71 mL/100 g/min. The mean perfusion values of 24 patients with moderately differentiated gastric adenocarcinoma were as follows: BF, 110.01 ± 31.90 mL/100 g/min; BV, 18.18 ± 5.62 mL/100 g; MTT, 9.81 ± 3.69 s; and PS, 40.08 ± 15.82 mL/100 g/min. The mean perfusion values of 16 patients with poorly differentiated gastric adenocarcinoma were as follows: BF, 138.59 ± 38.09 mL/100 g/min; BV, 21.08 ± 4.11 mL/100 g; MTT, 9.47 ± 1.80 s; and PS, 57.50 ± 13.28 mL/100 g/min. Comparing the 3 groups, differences between the well-differentiated group and the moderate differentiation group were all statistically significant for BF, BV, and PS (p < 0.05, respectively), differences between the well-differentiated group and the poor differentiation group were all statistically significant for BF, BV, and PS (p < 0.05,respectively) as well; While MTT value showed no statistical difference among the 3 groups (p > 0.05).
CONCLUSION
Stomach CT perfusion imaging is a functional imaging technology from the perspective of hemodynamics with potential clinical applications. The BF, BV and PS values could serve as indicators of the degree of malignancy and aid in prognostic assessment of gastric cancer.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.