MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00003226-200210000-00003

Медицинская библиотека · Cornea · 2002

Corneal neovascularization after nonmechanical versus mechanical corneal trephination for non-high-risk keratoplasty.

Cursiefen Claus, Martus Peter, Nguyen Nhung X, Langenbucher Achim, Seitz Berthold, Küchle Michael

Клиническое исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: To analyze the influence of mechanical versus nonmechanical trephination of donor and host corneas on superficial, peripheral corneal neovascularization occurring after non-high-risk keratoplasty.

METHODS

Patients of the prospective Erlangen non-high-risk keratoplasty study with standardized corneal photographs taken preoperatively and 1 year later were analyzed (n = 184). Slides of these photographs were projected (magnification x100) and corneal vessels graded in a standardized semiquantitative fashion into five categories with regard to limbus, sutures, and host-graft junction in each of 12 corneal sectors. Degree (total increase of grades in the 12 sectors) and maximal extent of corneal neovascularization (maximal centripetal extension of blood vessels) were analyzed. In 32 patients mechanical (17%) and in 152 nonmechanical trephination of host and donor tissue was performed (193-nm excimer laser, 83%). Statistical analysis was done using Fisher's exact and Mann-Whitney test.

RESULTS

Corneal neovascularization within the first postoperative year was lower in the nonmechanical [73 of 152 (48%)] compared with mechanical trephination group [24 of 32 (75%); p< 0.01; Mann-Whitney test]. Maximal extent of neovascularization (i.e., vessels reaching the interface or growing beyond) was not yet significantly different between nonmechanical (8%) and mechanical (17%) trephination (p = 0.074).

CONCLUSIONS

Nonmechanical trephination using the 193-nm excimer laser in non-high-risk keratoplasties might reduce corneal neovascularization occurring within the first postoperative year. This indicates that in the non-high-risk setting, development of postoperative corneal neovascularization may be affected by the trephination technique and subsequent wound-healing response.

Для цитирования: Cursiefen Claus, Martus Peter, Nguyen Nhung X, Langenbucher Achim, Seitz Berthold, Küchle Michael. Corneal neovascularization after nonmechanical versus mechanical corneal trephination for non-high-risk keratoplasty.. Cornea. 2002. DOI: 10.1097/00003226-200210000-00003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.