MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jmri.10436

Медицинская библиотека · Journal of magnetic resonance imaging : JMRI · 2004

Assessment of anal fistulas with high-resolution subtraction MR-fistulography: comparison with surgical findings.

Schaefer Oliver, Lohrmann Christian, Langer Mathias

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To investigate a new MR-imaging protocol defined as subtraction MR-fistulography for the detection of fistula-in-ano.

MATERIALS AND

METHODS

A total of 36 patients (18 men, 18 women) with the clinical diagnosis of anal fistula or abscess who were scheduled for surgical exploration were preoperatively imaged at 1.5 T in the supine position; coronal STIR sequences and axial T1-weighted three-dimensional FLASH sequences before and after intravenous injection of gadobenate dimeglumine (Gd-BOPTA) were obtained. Image subtraction was routinely used. The image findings were compared with the findings at surgical exploration according to a uniform classification system.

RESULTS

A total of 46 fistulas were seen on subtraction MR-fistulography, whereas surgery described 41 fistulas. MRI and surgery concordantly depicted a total number of 40 fistulas, six fistulas were only described by MRI, and one fistula was only seen during surgery. A total of 27 abscesses were detected with MRI, compared to 22 during surgery. A total of 22 abscesses were concordantly diagnosed. Complete agreement between subtraction MR-fistulography and surgery occurred in 32 (89%) of the 36 patients. The four patients in whom both procedures disagreed had complex anal sepsis with multiple fistulas and/or abscesses due to Crohn disease.

CONCLUSION

High-resolution subtraction MR-fistulography is an important complement to surgical exploration and especially suitable for investigating complex anal sepsis.

Для цитирования: Schaefer Oliver, Lohrmann Christian, Langer Mathias. Assessment of anal fistulas with high-resolution subtraction MR-fistulography: comparison with surgical findings.. Journal of magnetic resonance imaging : JMRI. 2004. DOI: 10.1002/jmri.10436.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.