A prospective RCT comparing combined chromoendoscopy with water exchange (CWE) vs water exchange (WE) vs air insufflation (AI) in adenoma detection in screening colonoscopy.

Leung J W, Yen A W, Jia H, Opada C, Melnik A, Atkins J, Feller C, Wilson M D, Leung F W

Клиническое исследование IV фазыСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A low adenoma detection rate (ADR) increases risks of interval cancers (ICs). Proximal colon flat polyps, e.g. serrated lesions (SLs), are difficult to find. Missed proximal colon flat lesions likely contribute to IC.

AIMS: We compared chromoendoscopy with water exchange (CWE), water exchange (WE) and air insufflation (AI) in detecting adenomas in screening colonoscopy.

METHODS

After split-dose preparation, 480 veterans were randomized to AI, WE and CWE.

RESULTS

Primary outcome of proximal ADR (55.6% vs 53.4% vs 52.2%, respectively) were similar in all groups. Adenoma per colonoscopy (APC) and adenoma per positive colonoscopy (APPC) were comparable. Detection rate of proximal colon SLs was significantly higher for CWE and WE than AI (26.3%, 23.6% and 11.3%, respectively, p = 0.002). Limitations: single operator; SLs only surrogate markers of but not IC.

CONCLUSIONS

When an endoscopist achieves high-quality AI examinations with overall ADR twice (61.6%) the recommended standard (30%), use of WE and CWE does not produce further improvement in proximal or overall ADR. Comparable APC and APPC confirm equivalent withdrawal inspection techniques. WE alone is sufficient to significantly improve detection of proximal SLs. The impact of increased detection of proximal SLs by WE on prevention of IC deserves to be studied. This study is registered at ClinicalTrial.gov (NCT#01607255).

Для цитирования: Leung J W, Yen A W, Jia H, Opada C, Melnik A, Atkins J, Feller C, Wilson M D, Leung F W. A prospective RCT comparing combined chromoendoscopy with water exchange (CWE) vs water exchange (WE) vs air insufflation (AI) in adenoma detection in screening colonoscopy.. United European gastroenterology journal. 2019. DOI: 10.1177/2050640619832196.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.