Comparison of Mammography and Mammography with Supplemental Whole-Breast US Tomography for Cancer Detection in Patients with Dense Breasts.

Yamashita Mary W, Larsen Linda H, Perez Jeremiah, Edwards Alexandra V, Papaioannou John, Jiang Yulei

СтатьяСравнительное исследованиеМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Women with dense breasts benefit from supplemental cancer screening with US, but US has low specificity.

PURPOSE: To evaluate the performance of breast US tomography (UST) combined with full-field digital mammography (FFDM) compared with FFDM alone for breast cancer screening in women with dense breasts.

MATERIALS AND

METHODS

This retrospective multireader multicase study included women with dense breasts who underwent FFDM and UST at 10 centers between August 2017 and October 2019 as part of a prospective case collection registry. All patients in the registry with cancer were included; patients with benign biopsy or negative follow-up imaging findings were randomly selected for inclusion. Thirty-two Mammography Quality Standards Act-qualified radiologists independently evaluated FFDM followed immediately by FFDM plus UST for suspicious findings and assigned a Breast Imaging Reporting and Data System (BI-RADS) category. The superiority of FFDM plus UST versus FFDM alone for cancer detection (assessed with area under the receiver operating characteristic curve [AUC]), BI-RADS 4 sensitivity, and BI-RADS 3 sensitivity and specificity were evaluated using the two-sided significance level of α = .05. Noninferiority of BI-RADS 4 specificity was evaluated at the one-sided significance level of α = .025 with a -10% margin.

RESULTS

Among 140 women (mean age, 56 years ±10 [SD]; 36 with cancer, 104 without), FFDM plus UST achieved superior performance compared with FFDM alone (AUC, 0.60 [95% CI: 0.51, 0.69] vs 0.54 [95% CI: 0.45, 0.64]; P = .03). For FFDM plus UST versus FFDM alone, BI-RADS 4 mean sensitivity was superior (37% [428 of 1152] vs 30% [343 of 1152]; P = .03) and BI-RADS 4 mean specificity was noninferior (82% [2741 of 3328] vs 88% [2916 of 3328]; P = .004). For FFDM plus UST versus FFDM, no difference in BI-RADS 3 mean sensitivity was observed (40% [461 of 1152] vs 33% [385 of 1152]; P = .08), but BI-RADS 3 mean specificity was superior (75% [2491 of 3328] vs 69% [2299 of 3328]; P = .04).

CONCLUSION

In women with dense breasts, FFDM plus UST improved cancer detection by radiologists versus FFDM alone. Clinical trial registration nos. NCT03257839 and NCT04260620 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Mann in this issue.

Для цитирования: Yamashita Mary W, Larsen Linda H, Perez Jeremiah, Edwards Alexandra V, Papaioannou John, Jiang Yulei. Comparison of Mammography and Mammography with Supplemental Whole-Breast US Tomography for Cancer Detection in Patients with Dense Breasts.. Radiology. 2024. DOI: 10.1148/radiol.231680.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.