MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s12282-024-01580-8

Медицинская библиотека · Breast cancer (Tokyo, Japan) · 2024

Inter- and intra-observer variability of qualitative visual breast-composition assessment in mammography among Japanese physicians: a first multi-institutional observer performance study in Japan.

Koyama Yoichi, Nakashima Kazuaki, Orihara Shunichiro, Tsunoda Hiroko, Kimura Fuyo, Uenaka Natsuki, Ban Kanako, Michishita Yukiko, Kanemaki Yoshihide, Kurihara Arisa, Tawaraya Kanae, Taguri Masataka, Ishikawa Takashi, Uematsu Takayoshi

СтатьяМногоцентровое исследованиеПеревод пока не подготовлен

Аннотация

BACKGROUND

Visual assessment of mammographic breast composition remains the most common worldwide, although subjective variability limits its reproducibility. This study aimed to investigate the inter- and intra-observer variability in qualitative visual assessment of mammographic breast composition through a multi-institutional observer performance study for the first time in Japan.

METHODS

This study enrolled 10 Japanese physicians from five different institutions. They used the new Japanese breast-composition classification system 4th edition to subjectively evaluate the breast composition in 200 pairs of right and left normal mediolateral oblique mammograms (number determined using precise sample size calculations) twice, with a 1-month interval (median patient age: 59 years [range 40-69 years]). The primary endpoint of this study was the inter-observer variability using kappa (κ) value.

RESULTS

Inter-observer variability for the four and two classes of breast-composition assessment revealed moderate agreement (Fleiss' κ: first and second reading = 0.553 and 0.587, respectively) and substantial agreement (Fleiss' κ: first and second reading = 0.689 and 0.70, respectively). Intra-observer variability for the four and two classes of breast-composition assessment demonstrated substantial agreement (Cohen's κ, median = 0.758) and almost perfect agreement (Cohen's κ, median = 0.813). Assessments of consensus between the 10 physicians and the automated software Volpara® revealed slight agreement (Cohen's κ; first and second reading: 0.104 and 0.075, respectively).

CONCLUSIONS

Qualitative visual assessment of mammographic breast composition using the new Japanese classification revealed excellent intra-observer reproducibility. However, persistent inter-observer variability, presenting a challenge in establishing it as the gold standard in Japan.

Для цитирования: Koyama Yoichi, Nakashima Kazuaki, Orihara Shunichiro, Tsunoda Hiroko, Kimura Fuyo, Uenaka Natsuki, Ban Kanako, Michishita Yukiko, Kanemaki Yoshihide, Kurihara Arisa, Tawaraya Kanae, Taguri Masataka, Ishikawa Takashi, Uematsu Takayoshi. Inter- and intra-observer variability of qualitative visual breast-composition assessment in mammography among Japanese physicians: a first multi-institutional observer performance study in Japan.. Breast cancer (Tokyo, Japan). 2024. DOI: 10.1007/s12282-024-01580-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.