DOI 10.1016/j.ejrad.2024.111440
High-resolution diffusion-weighted MRI plus mammography for detecting clinically occult breast cancers in women with dense breasts.
Аннотация
PURPOSE: To compare the performance of mammography, high-resolution DW-MRI, DCE-MRI, and their combinations in detecting clinically occult breast cancer in women with dense breasts.
METHOD: 544 breasts from 281 consecutive asymptomatic women with dense breasts were retrospectively identified. They underwent breast MRI for preoperative evaluation of breast cancers (n = 214) or as supplemental screening (n = 67) including DCE-MRI and DW-MRI (b values, 0 and 1000 sec/mm2; in-plane resolution, 1.1 × 1.1 mm2 and 1.3 × 1.3 mm2; section thickness, 3 mm), in addition to mammography. Three readers independently reviewed each examination on a per-breast basis. Histopathology and at least two year of imaging follow-up served as the gold standard. The sensitivities and specificities of different imaging modalities were compared using McNemar test.
RESULTS
230 of 544 breasts (42 %) had malignant lesions. The sensitivity of DW-MRI was higher than that of mammography (77.0 % vs 57.9 %; adjusted p < 0.001), but lower than that of DCE-MRI (84.8 %; adjusted p = 0.014). The specificity of DW-MRI was comparable to those of mammography (98.1 % vs 99.1 %; adjusted p > 0.999) and DCE-MRI (97.1 %; adjusted p > 0.999). DW-MRI plus mammography had a comparable sensitivity and specificity to those of DCE-MRI plus mammography (88.6 % vs 90.9 % and 97.1 % vs 96.2 %; adjusted p > 0.999 for both).
CONCLUSIONS
High-resolution DW-MRI had a sensitivity higher than mammography and lower than DCE-MRI. Nevertheless, DW-MRI plus mammography showed a comparable sensitivity and specificity to DCE-MRI plus mammography for detecting clinically occult cancers in women with dense breasts.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.