MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11604-024-01533-3

Медицинская библиотека · Japanese journal of radiology · 2024

Exploration of tumor size measurement methods in preoperative breast cancer assessment using whole-body silicon photomultiplier PET: feasibility and first results.

Kuroda Hiroyuki, Yoshizako Takeshi, Yada Nobuhiro, Kamimura Tomomi, Yamamoto Nobuko, Maruyama Mitsunari, Yoshida Rika, Fukuda Mizuki, Kataoka Yuko, Itakura Masayuki, Kaji Yasushi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Whole-body silicon photomultiplier positron emission tomography (WB SiPM PET) could be used to diagnose breast cancer spread before lumpectomy. We aimed to investigate the method of measuring the tumor size by WB SiPM PET as a basis for diagnosing breast cancer spread in the breast.

MATERIALS AND

METHODS

We retrospectively reviewed 35 breast cancer lesions in 32 patients who underwent WB SiPM PET/CT in the prone position as preoperative breast cancer examinations from September 2020 to March 2022. In all cases, a 20-mm spherical VOI was placed in the normal mammary gland to measure the mean standardised uptake value (SUVmean) and the standard deviation (SD) of 18F-fluorodeoxyglucose (FDG) uptake. We prepared four types of candidates (SUVmean + 2 SD, SUVmean + 3 SD, 1.5 SUVmean + 2 SD, 1.5 SUVmean + 3 SD) for thresholds for delineating tumor contours on PET images. On the semiautomatic viewer soft, the maximum tumor sizes were measured at each of the four thresholds and compared with the pathological tumor sizes, including the extensive intraductal component (EIC).

RESULTS

The lesion detection sensitivity was 97% for WB SiPM PET. PET detected 34 lesions, excluding 4-mm ductal carcinomas in situ (DCIS). PET measurements at the '1.5 SUVmean + 2 SD' threshold demonstrated values closest to the pathological tumor sizes, including EIC. Moreover, '1.5 SUVmean + 2 SD' had the highest concordance (63%).

CONCLUSIONS

The study demonstrated that among various PET thresholds, the '1.5 SUVmean + 2 SD' threshold exhibited the best performance. However, even with this threshold, the concordance rate was limited to only 63%.

Для цитирования: Kuroda Hiroyuki, Yoshizako Takeshi, Yada Nobuhiro, Kamimura Tomomi, Yamamoto Nobuko, Maruyama Mitsunari, Yoshida Rika, Fukuda Mizuki, Kataoka Yuko, Itakura Masayuki, Kaji Yasushi. Exploration of tumor size measurement methods in preoperative breast cancer assessment using whole-body silicon photomultiplier PET: feasibility and first results.. Japanese journal of radiology. 2024. DOI: 10.1007/s11604-024-01533-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.