Diagnostic accuracy of galactomannan and lateral flow assay in invasive aspergillosis: A diagnostic meta-analysis.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Zhang Xiaohong, Shang Xue, Zhang Yinghua, Li Xiuxia, Yang Kehu, Wang Yan, Guo Kangle
Аннотация
BACKGROUND: Efficient diagnosis of patients at high risk for invasive aspergillosis (IA) improves the outcome of the disease. Lateral flow assay (LFA) is a novel technology and assessing its diagnostic accuracy is of great significance in the clinical management of IA.
METHODS: A meta-analysis using case-control studies was performed to assess the diagnostic performance of LFA alone or galactomannan (GM) combined with LFA (GM-LFA) as screening tests for IA. The sensitivity, specificity, and summary receiver operating characteristic curves were constructed.
RESULTS: Nineteen studies with 2838 patients were included. The pooled effect sizes for different indicators included: sensitivity (77 % for LFA and 75 % for GM-LFA), specificity (88 % for LFA and 87 % for GM-LFA), positive likelihood ratio (6.65 for LFA and 12.02 for GM-LFA), negative likelihood ratio (0.26 for LFA and 0.27 for GM-LFA), and the diagnostic odds ratio (25.81 for LFA and 44.87 for GM-LFA). The area under the curve was 0.91 for LFA and 0.94 for GM-LFA with a cut-off value ≥ 0.5.
CONCLUSION: The present meta-analysis suggested that LFA or GM-LFA at an optical density index (ODI) cutoff of ≥0.5 was a useful diagnostic tool for IA in patients. The results showed no significant differences in the accuracy of LFA alone and GM-LFA in diagnosing IA. In the clinical diagnosis and treatment of IA, LFA can be recommended if timely results are needed.
METHODS: A meta-analysis using case-control studies was performed to assess the diagnostic performance of LFA alone or galactomannan (GM) combined with LFA (GM-LFA) as screening tests for IA. The sensitivity, specificity, and summary receiver operating characteristic curves were constructed.
RESULTS: Nineteen studies with 2838 patients were included. The pooled effect sizes for different indicators included: sensitivity (77 % for LFA and 75 % for GM-LFA), specificity (88 % for LFA and 87 % for GM-LFA), positive likelihood ratio (6.65 for LFA and 12.02 for GM-LFA), negative likelihood ratio (0.26 for LFA and 0.27 for GM-LFA), and the diagnostic odds ratio (25.81 for LFA and 44.87 for GM-LFA). The area under the curve was 0.91 for LFA and 0.94 for GM-LFA with a cut-off value ≥ 0.5.
CONCLUSION: The present meta-analysis suggested that LFA or GM-LFA at an optical density index (ODI) cutoff of ≥0.5 was a useful diagnostic tool for IA in patients. The results showed no significant differences in the accuracy of LFA alone and GM-LFA in diagnosing IA. In the clinical diagnosis and treatment of IA, LFA can be recommended if timely results are needed.