m+Medelevator.RU
← Поиск публикаций
Drug design, development and therapy · 2014

Caval filters in intensive care: a retrospective study.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ferraro F, Di Gennaro T L, Torino A, Petruzzi J, d'Elia A, Fusco P, Marfella R, Lettieri B

Аннотация

AIM: To evaluate the effectiveness of a caval vein filter (CVF) peri-implant monitoring protocol in order to reduce pulmonary embolism (PE) mortality and CVF-related morbidity.

BACKGROUND: The reduction in mortality from PE associated with the use of CVF is affected by the risk of increase in morbidity. Therefore, CVF implant is a challenging prophylactic or therapeutic option. Nowadays, we have many different devices whose rational use, by applying a strict peri-implant monitoring protocol, could be safe and effective.

MATERIALS AND METHODS: We retrospectively studied 62 patients of a general Intensive Care Unit (ICU) scheduled for definitive, temporary, or optional bedside CVF implant. A peri-implant monitoring protocol including a phlebocavography, an echo-Doppler examination, and coagulation tests was adopted.

RESULTS: In our study, no thromboembolic recurrence was registered. We implanted 48 retrievable and only 20 definitive CVFs. Endothelial adhesion (18%), residual clot (5%), cranial or caudal migration (6%), microbial colonization of the filter in the absence of clinical signs of infection (1%), caval thrombosis (1%), and pneumothorax (1%) were reported. Deep-vein thrombosis (DVT) was reported (8%) as early complication. All patients with DVT had a temporary or optional filter implanted. However, in our cohort, definitive CVFs were reserved only to 32% of patients and they were not associated with DVT as complication.

CONCLUSION: CVF significantly reduces iatrogenic PE without affecting mortality. Generally, ICU patients have a transitory thromboembolic risk, and so the temporary CVF has been proved to be a first-line option to our cohort. A careful monitoring may contribute to a satisfactory outcome in order to promote CVF implant as a safe prophylaxis option.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты