MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00062-023-01269-z

Медицинская библиотека · Clinical neuroradiology · 2023

Prone Dynamic CT Myelography in Spontaneous Intracranial Hypotension : Diagnostic Need and Radiation Doses.

Lützen Niklas, Barvulsky Aleman Enrique, Fung Christian, Beck Juergen, Urbach Horst

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND AND PURPOSE: The diagnostic work-up in patients with spontaneous intracranial hypotension (SIH) and spinal longitudinal extradural CSF collection (SLEC) on magnetic resonance imaging (MRI) comprises dynamic digital subtraction myelography (dDSM) in prone position for leak detection. Dynamic computed tomography (CT) myelography (dCT-M) in prone position follows if the leak is not unequivocally located. A drawback of dCT‑M is a high radiation dose. This study evaluates the diagnostic needs of dCT-M examinations and measures to reduce radiation doses.

METHODS

Frequency, leak sites, length and number of spiral acquisitions, DLP and effective doses of dCT‑M were retrospectively recorded in patients with ventral dural tears.

RESULTS

Of 42 patients with ventral dural tears, 8 underwent 11 dCT‑M when the leak was not unequivocally shown on digital subtraction myelography. The median number of spiral acquisitions was 4 (range 3-7) and the mean effective radiation dose 30.6 mSv (range 13.1-62.16 mSv) mSv. Five of eight leaks were located in the upper thoracic spine (range C7/Th1-Th2/3). Bolus tracking of intrathecal contrast agent in dCT‑M was used to limit the number and length of spiral acquisitions.

DISCUSSION: A dCT‑M in prone position to localize a ventral dural tear is needed in every fifth patient with a SLEC on MRI. It is typically needed when the leak is located in the upper thoracic spine and when patients have broad shoulders. Measures to reduce the radiation dose include bolus tracking or to repeat the DSM with adjusted positioning of patient.

Для цитирования: Lützen Niklas, Barvulsky Aleman Enrique, Fung Christian, Beck Juergen, Urbach Horst. Prone Dynamic CT Myelography in Spontaneous Intracranial Hypotension : Diagnostic Need and Radiation Doses.. Clinical neuroradiology. 2023. DOI: 10.1007/s00062-023-01269-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.