MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/15563650.2024.2323092

Медицинская библиотека · Clinical toxicology (Philadelphia, Pa.) · 2024

Optic nerve sheath diameter measurements to predict delayed neurological sequelae after carbon monoxide poisoning.

Tekin Yusuf Kenan

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Delayed neurological sequelae are a major complication of carbon monoxide poisoning. However, today there is still no objective screening tool for predicting delayed neurological sequelae in patients with carbon monoxide poisoning. The present study aimed to assess the usefulness of optic nerve sheath diameter measurements in predicting delayed neurological sequelae after carbon monoxide poisoning.

METHODS

In this retrospective study, patients with a diagnosis of carbon monoxide poisoning in the emergency department from 2010 to 2021 were included in the study. Right and left optic nerve sheath diameters were calculated based on cranial computed tomography scans, and the presence of delayed neurological sequelae was evaluated.

RESULTS

The mean (± standard deviation) optic nerve sheath diameter in patients who developed delayed neurological sequelae was statistically significantly greater on both the right and left compared to patients who did not develop delayed neurological sequelae (right; 5.02 ± 0.06 mm versus 4.89 ± 0.07 mm, P < 0.001; left; 5.03 ± 0.09 mm versus 4.85 ± 0.10 mm, P < 0.001). A multivariate linear regression analysis revealed that carboxyhemoglobin and both right and left optic nerve sheath diameter were the factors associated with the delayed neurological sequelae.

DISCUSSION: The present study revealed that optic nerve sheath diameter measurements may be a useful screening tool to predict delayed neurological sequelae after carbon monoxide poisoning. The ability to predict a poor neurological prognosis in carbon monoxide poisoning is important for initiating early rehabilitation interventions and make help future trials. Limitations of this study include that normal optic nerve sheath diameters are not well established, and that not every patient underwent computed tomography.

CONCLUSIONS

Optic nerve sheath diameters measurements may be a helpful screening tool for predicting delayed neurological sequelae after carbon monoxide poisoning.

Для цитирования: Tekin Yusuf Kenan. Optic nerve sheath diameter measurements to predict delayed neurological sequelae after carbon monoxide poisoning.. Clinical toxicology (Philadelphia, Pa.). 2024. DOI: 10.1080/15563650.2024.2323092.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.