MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11605-017-3574-z

Медицинская библиотека · Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract · 2017

Utility of Endoanal Ultrasonography in Assessment of Primary and Recurrent Anal Fistulas and for Detection of Associated Anal Sphincter Defects.

Emile Sameh Hany, Magdy Alaa, Youssef Mohamed, Thabet Waleed, Abdelnaby Mahmoud, Omar Waleed, Khafagy Wael

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Tridimensional endoanal ultrasonography (3D-EAUS) has been used for the assessment of various anorectal lesions. Previous studies have reported good accuracy of 3D-EAUS in preoperative assessment of fistula-in-ano (FIA). This study aimed to assess the diagnostic utility of 3D-EAUS in preoperative evaluation of primary and recurrent FIA and its role in detection of associated anal sphincter (AS) defects.

PATIENTS AND

METHODS

Prospectively collected data of patients with FIA who were investigated with 3D-EAUS were reviewed. The findings of EAUS were compared with the intraoperative findings, the reference standard, to find the degree of agreement regarding the position of the internal opening (IO) and primary tract (PT), and presence of secondary tracts using kappa (k) coefficient test. A subgroup analysis was performed to compare the accuracy and sensitivity of EAUS for primary and recurrent FIA.

RESULTS

Of the patients, 131 were included to the study. EAUS had an overall accuracy of 87, 88.5, and 89.5% in detection of IO, PT, and AS defects, respectively. There was very good concordance between the findings of EAUS and intraoperative findings for the investigated parameters (kappa = 0.748, 0.83, 0.935), respectively. Accuracy and sensitivity of EAUS in recurrent FIA were insignificantly lower than primary cases. EAUS detected occult AS defects in 5.3% of the patients studied.

CONCLUSION

The diagnostic utility of 3D-EAUS was comparable in primary and recurrent FIA. 3D-EAUS was able to detect symptomatic and occult AS defects with higher accuracy than clinical examination.

Для цитирования: Emile Sameh Hany, Magdy Alaa, Youssef Mohamed, Thabet Waleed, Abdelnaby Mahmoud, Omar Waleed, Khafagy Wael. Utility of Endoanal Ultrasonography in Assessment of Primary and Recurrent Anal Fistulas and for Detection of Associated Anal Sphincter Defects.. Journal of gastrointestinal surgery : official journal of the Society for Surgery of the Alimentary Tract. 2017. DOI: 10.1007/s11605-017-3574-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.