Diseases of the colon and rectum · 2015
Prospective multicenter study of a synthetic bioabsorbable anal fistula plug to treat cryptoglandular transsphincteric anal fistulas.
Клиническое исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Stamos Michael J, Snyder Michael, Robb Bruce W, Ky Alex, Singer Marc, Stewart David B, Sonoda Toyooki, Abcarian Herand
Аннотация
BACKGROUND: Although interest in sphincter-sparing treatments for anal fistulas is increasing, few large prospective studies of these approaches have been conducted.
OBJECTIVE: The study assessed outcomes after implantation of a synthetic bioabsorbable anal fistula plug.
DESIGN: A prospective, multicenter investigation was performed.
SETTING: The study was conducted at 11 colon and rectal centers.
PATIENTS: Ninety-three patients (71 men; mean age, 47 years) with complex cryptoglandular transsphincteric anal fistulas were enrolled. Exclusion criteria included Crohn's disease, an active infection, a multitract fistula, and an immunocompromised status.
INTERVENTION: Draining setons were used at the surgeon's discretion. Patients had follow-up evaluations at 1, 3, 6, and 12 months postoperatively.
MAIN OUTCOME MEASURES: The primary end point was healing of the fistula, defined as drainage cessation plus closure of the external opening, at 6 and 12 months. Secondary end points were fecal continence, duration of drainage from the fistula, pain, and adverse events during follow-up.
RESULTS: Thirteen patients were lost to follow-up and 21 were withdrawn, primarily to undergo an alternative treatment. The fistula healing rates at 6 and 12 months were 41% (95% CI, 30%-52%; total n = 74) and 49% (95% CI, 38%-61%; total n = 73). Half the patients in whom a previous treatment failed had healing. By 6 months, the mean Wexner score had improved significantly (p = 0.0003). By 12 months, 93% of patients had no or minimal pain. Adverse events included 11 infections/abscesses, 2 new fistulas, and 8 total and 5 partial plug extrusions. The fistula healed in 3 patients with a partial extrusion.
LIMITATIONS: The study was nonrandomized and had relatively high rates of loss to follow-up.
CONCLUSION: Implantation of a synthetic bioabsorbable fistula plug is a reasonably efficacious treatment for complex transsphincteric anal fistulas, especially given the simplicity and low morbidity of the procedure.
OBJECTIVE: The study assessed outcomes after implantation of a synthetic bioabsorbable anal fistula plug.
DESIGN: A prospective, multicenter investigation was performed.
SETTING: The study was conducted at 11 colon and rectal centers.
PATIENTS: Ninety-three patients (71 men; mean age, 47 years) with complex cryptoglandular transsphincteric anal fistulas were enrolled. Exclusion criteria included Crohn's disease, an active infection, a multitract fistula, and an immunocompromised status.
INTERVENTION: Draining setons were used at the surgeon's discretion. Patients had follow-up evaluations at 1, 3, 6, and 12 months postoperatively.
MAIN OUTCOME MEASURES: The primary end point was healing of the fistula, defined as drainage cessation plus closure of the external opening, at 6 and 12 months. Secondary end points were fecal continence, duration of drainage from the fistula, pain, and adverse events during follow-up.
RESULTS: Thirteen patients were lost to follow-up and 21 were withdrawn, primarily to undergo an alternative treatment. The fistula healing rates at 6 and 12 months were 41% (95% CI, 30%-52%; total n = 74) and 49% (95% CI, 38%-61%; total n = 73). Half the patients in whom a previous treatment failed had healing. By 6 months, the mean Wexner score had improved significantly (p = 0.0003). By 12 months, 93% of patients had no or minimal pain. Adverse events included 11 infections/abscesses, 2 new fistulas, and 8 total and 5 partial plug extrusions. The fistula healed in 3 patients with a partial extrusion.
LIMITATIONS: The study was nonrandomized and had relatively high rates of loss to follow-up.
CONCLUSION: Implantation of a synthetic bioabsorbable fistula plug is a reasonably efficacious treatment for complex transsphincteric anal fistulas, especially given the simplicity and low morbidity of the procedure.