MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ejcts/ezab093

Медицинская библиотека · European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery · 2021

Thromboembolic complications in transfemoral aortic valve implantation due to aortic wall thrombus and shaggy aorta syndrome.

Haensig Martin, Kuntze Thomas, Gonzalez-Lopez David, Lapp Harald, Lauten Philipp, Owais Tamer

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Aortic wall thrombus (AWT) can affect suitability to endovascular repair, while its most aggressive entity is better known as shaggy aorta syndrome. Primary objective was to study the procedural and clinical outcome with regard to atherothrombotic AWT in transfemoral aortic valve implantation.

METHODS

In a retrospective, single-centre analysis, a qualitative 0-10 AWT score classification system was used. The most severely affected aortic area in computed tomography angiography cross-section was assessed for the number of affected segments, thrombus type, thickness, area and circumference. Primary endpoints were 30-day mortality, neurologic, renal and pulmonary events and signs of solid organ infarction.

RESULTS

Between November 2017 and September 2019, 604 patients underwent transfemoral transcatheter aortic valve implantation in our institution. Computed tomography-guided analysis revealed AWT in 11.3% and shaggy aorta syndrome in 6 patients (1.0% with 83.3% male). AWT was mainly present in the descending thoracic and abdominal aorta and was associated with acute renal failure (11.8% vs 3.2%, P ≤ 0.001) and a seven-fold increased rate of disabling peri-interventional stroke (4.4% vs 0.6%, P ≤ 0.001). In all patients with disabling peri-interventional stroke a balloon-expandable prosthesis was used (P ≤ 0.001). In case of shaggy aorta, mortality was more than six-fold increased (2.8% vs 16.7%, P = 0.046).

CONCLUSIONS

Severe and irregular thrombus of the descending thoracic and abdominal aorta has been strongly associated with acute respiratory failure and peri-interventional stroke in transfemoral aortic valve implantation, being more likely using balloon-expandable devices. Our results imply important changes with regard to device design and present international transcatheter aortic valve implantation guidelines.

Для цитирования: Haensig Martin, Kuntze Thomas, Gonzalez-Lopez David, Lapp Harald, Lauten Philipp, Owais Tamer. Thromboembolic complications in transfemoral aortic valve implantation due to aortic wall thrombus and shaggy aorta syndrome.. European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery. 2021. DOI: 10.1093/ejcts/ezab093.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.