DOI 10.1007/s10840-022-01425-4
Inter-American Society of Cardiology (CIFACAH-ELECTROSIAC) and Latin-American Heart Rhythm Society (LAHRS): multidisciplinary review on the appropriate use of implantable cardiodefibrillator in heart failure with reduced ejection fraction.
Аннотация
BACKGROUND
Our main objective was to present a multidisciplinary review on the epidemiology of sudden cardiac death (SCD) and the tools that could be used to identify malignant ventricular arrhythmias (VAs) and to perform risk stratification. In addition, indications and contraindications for the use of implantable cardioverter defibrillator (ICD) in general and in special populations including the elderly and patients with chronic kidney disease (CKD) are also given.
METHODS
An expert group from the Inter American Society of Cardiology (IASC), through their HF Council (CIFACAH) and Electrocardiology Council (ElectroSIAC), together with the Latin American Heart Rhythm Society (LAHRS), reviewed and discussed the literature regarding the appropriate use of an ICD in people with heart failure (HF) with reduced ejection fraction (HFpEF). Indications and contraindications for the use of ICD are presented in this multidisciplinary review.
RESULTS
Numerous clinical studies have demonstrated the usefulness of ICD in both primary and secondary prevention of SCD in HFpEF. There are currently precise indications and contraindications for the use of these devices.
CONCLUSIONS
In some Latin American countries, a low rate of implantation is correlated with low incomes, but this is not the case for all Latin America. Determinants of the low rates of ICD implantation in many Latin American countries are still a matter of research. VA remains one of the most common causes of cardiovascular death associated with HFrEF and different tools are available for stratifying the risk of SCD in this population.