Journal of computer assisted tomography · 2017
Reduced Field-of-View Diffusion-Weighted Magnetic Resonance Imaging of the Prostate at 3 Tesla: Comparison With Standard Echo-Planar Imaging Technique for Image Quality and Tumor Assessment.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Tamada Tsutomu, Ream Justin M, Doshi Ankur M, Taneja Samir S, Rosenkrantz Andrew B
Аннотация
OBJECTIVE: The purpose of this study was to compare image quality and tumor assessment at prostate magnetic resonance imaging (MRI) between reduced field-of-view diffusion-weighted imaging (rFOV-DWI) and standard DWI (st-DWI).
METHODS: A total of 49 patients undergoing prostate MRI and MRI/ultrasound fusion-targeted biopsy were included. Examinations included st-DWI (field of view [FOV], 200 × 200 mm) and rFOV-DWI (FOV, 140 × 64 mm) using a 2-dimensional (2D) spatially-selective radiofrequency pulse and parallel transmission. Two readers performed qualitative assessments; a third reader performed quantitative evaluation.
RESULTS: Overall image quality, anatomic distortion, visualization of capsule, and visualization of peripheral/transition zone edge were better for rFOV-DWI for reader 1 (P ≤ 0.002), although not for reader 2 (P ≥ 0.567). For both readers, sensitivity, specificity, and accuracy for tumor with a Gleason Score (GS) of 3 + 4 or higher were not different (P ≥ 0.289). Lesion clarity was higher for st-DWI for reader 2 (P = 0.008), although similar for reader 1 (P = 0.409). Diagnostic confidence was not different for either reader (P ≥ 0.052). Tumor-to-benign apparent diffusion coefficient ratio was not different (P = 0.675).
CONCLUSIONS: Potentially improved image quality of rFOV-DWI did not yield improved tumor assessment. Continued optimization is warranted.
METHODS: A total of 49 patients undergoing prostate MRI and MRI/ultrasound fusion-targeted biopsy were included. Examinations included st-DWI (field of view [FOV], 200 × 200 mm) and rFOV-DWI (FOV, 140 × 64 mm) using a 2-dimensional (2D) spatially-selective radiofrequency pulse and parallel transmission. Two readers performed qualitative assessments; a third reader performed quantitative evaluation.
RESULTS: Overall image quality, anatomic distortion, visualization of capsule, and visualization of peripheral/transition zone edge were better for rFOV-DWI for reader 1 (P ≤ 0.002), although not for reader 2 (P ≥ 0.567). For both readers, sensitivity, specificity, and accuracy for tumor with a Gleason Score (GS) of 3 + 4 or higher were not different (P ≥ 0.289). Lesion clarity was higher for st-DWI for reader 2 (P = 0.008), although similar for reader 1 (P = 0.409). Diagnostic confidence was not different for either reader (P ≥ 0.052). Tumor-to-benign apparent diffusion coefficient ratio was not different (P = 0.675).
CONCLUSIONS: Potentially improved image quality of rFOV-DWI did not yield improved tumor assessment. Continued optimization is warranted.