Journal of clinical ultrasound : JCU · 2017
Value of three-section contrast-enhanced transrectal ultrasonography in the detection of prostate cancer.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Qi Ting-Yue, Sun Hong-Guang, Li Nian-Fen, Feng Hao, Ding Yong-Ling, Wang Xiao-Xiang
Аннотация
BACKGROUND: To assess the efficacy of three-section contrast-enhanced transrectal ultrasonography (CETRUS) in prostate cancer (PCa) detection.
METHODS: A total of 169 consecutive patients with either PSA level ≥ 4 ng/ml or abnormal digital rectal examination findings were prospectively enrolled in this single center study. All patients underwent baseline transrectal ultrasonography (TRUS) and three-section CETRUS by one investigator blinded to any clinical data before TRUS-guided transperineal biopsy. The performances of baseline TRUS, single-section, and three-section CETRUS for PCa detection were compared.
RESULTS: On a per-patient basis, the sensitivity, specificity, and overall accuracy for detecting PCa with three-section CETRUS was 92.3%, 69.2%, and 78.1%, respectively. In comparison with conventional (single-section) CETRUS (sensitivity 75.4%, specificity 72.1%, and accuracy 73.4%), three-section CETRUS performed significantly better (p < 0.05, McNemar test). Additionally, the low-grade PCa detection rate for three-section CETRUS was significantly higher than that of conventional CETRUS (26.7% versus 10.2%, p < 0.05).
CONCLUSIONS: Our study demonstrated a significant benefit of three-section CETRUS relative to conventional CETRUS, and this technique may find more PCa patients eligible for active surveillance. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:304-309, 2017.
METHODS: A total of 169 consecutive patients with either PSA level ≥ 4 ng/ml or abnormal digital rectal examination findings were prospectively enrolled in this single center study. All patients underwent baseline transrectal ultrasonography (TRUS) and three-section CETRUS by one investigator blinded to any clinical data before TRUS-guided transperineal biopsy. The performances of baseline TRUS, single-section, and three-section CETRUS for PCa detection were compared.
RESULTS: On a per-patient basis, the sensitivity, specificity, and overall accuracy for detecting PCa with three-section CETRUS was 92.3%, 69.2%, and 78.1%, respectively. In comparison with conventional (single-section) CETRUS (sensitivity 75.4%, specificity 72.1%, and accuracy 73.4%), three-section CETRUS performed significantly better (p < 0.05, McNemar test). Additionally, the low-grade PCa detection rate for three-section CETRUS was significantly higher than that of conventional CETRUS (26.7% versus 10.2%, p < 0.05).
CONCLUSIONS: Our study demonstrated a significant benefit of three-section CETRUS relative to conventional CETRUS, and this technique may find more PCa patients eligible for active surveillance. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:304-309, 2017.