Automated Beta Zone Parapapillary Area Measurement to Differentiate Between Healthy and Glaucoma Eyes.
Аннотация
PURPOSE: To evaluate whether automated assessment of beta zone parapapillary atrophy (βPPA) area can differentiate between glaucomatous and healthy eyes of varying axial lengths (AL).
DESIGN
Cross-sectional study.
METHODS
βPPA was automatically identified in glaucoma and healthy eyes with enhanced-depth imaging optical coherence tomography (OCT) optic nerve head (ONH) radial B-scans. Associations with AL and the presence of glaucoma were assessed. Manually delineated βPPA on individual OCT ONH B-scans of 35 eyes from the Diagnostic Innovations in Glaucoma Study served to validate the automated method.
RESULTS
One hundred fifty-three glaucoma eyes (mean ± standard deviation) (visual field mean deviation, -5.0 ± 6.4 dB and mean AL, 25.1 ± 1.1 mm) and 73 healthy eyes (visual field mean deviation, 0.1 ± 1.4 dB and mean AL, 24.1 ± 1.1 mm) were included. In multivariable analysis, larger βPPA area was significantly associated with a diagnosis of glaucoma after controlling for age, central corneal thickness, and AL. Moreover, in multivariable analysis, the odds of having glaucoma were doubled for each 0.2 mm2 larger βPPA area. The age- and AL-adjusted area under the receiver operating characteristic curve (95% confidence interval) of βPPA area for differentiating between glaucoma and healthy eyes was 0.75 (0.68-0.81). Agreement for the location of the Bruch membrane opening and the location of retinal pigment epithelium tips was stronger between the automated technique and each individual observer than it was between the 2 observers.
CONCLUSIONS
Larger βPPA area, as determined by automated OCT assessment, is significantly associated with a diagnosis of glaucoma, even after adjusting for age and AL, and may aid in differentiating healthy from glaucomatous eyes.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.