The relation of lactate level and carbon dioxide pressure discrepancies between transcutaneous and arterial measurements.

Gürün Kaya Aslıhan, Özpinar Şeyda Nur, Öz Miraç, Erol Serhat, Arslan Fatma, Çiledağ Aydın, Kaya Akın

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

Partial carbondioxide pressure of the arterial blood (PaCO2) is used to evaluate alveolar ventilation. Transcutaneous carbon dioxide pressure (TcCO2) monitoring has been developed as a non-invasive (NIV) alternative to arterial blood gas analysis (ABG). Studies have shown that decreased tissue perfusion leads to increased carbondioxide (CO2). The use of transcutaneous capnometry may be unreliable in patients with perfusion abnormalities. In this study, we aimed to evaluate the relation between TcCO2-PaCO2 and lactate level which is recognized as a marker of hypoperfusion.

MATERIALS AND

METHODS

In this prospective cohort study in critical care patients with hypercapnic respiratory failure (PaCO2 ≥45 mmHg) who received NIV between April 2019 and January 2020 in the intensive care unit were enrolled in the study. Patients' simultaneously measured TcCO2 and PaCO2 values of hypercapnic patients were recorded. Each paired measurement was categorized into two groups; normal lactate (<2 mmol/L) and increased lactate (≥2 mmol/L).

RESULT: A total of 116 paired TcCO2 and PaCO2 measurements of 29 patients were recorded. Bland-Altman analysis showed the mean bias between the TcCO2 and PaCO2 and 95% limits of agreement (LOA) in all measurements (1.75 mmHg 95% LOA -3.67 to 7.17); in the normal lactate group (0.66 mmHg 95% LOA -1.71 to 3.03); and in the increased lactate group (5.17 mmHg 95% LOA -1.63 to 11.97). The analysis showed a correlation between lactate level and the difference between TcCO2 and PaCO2 (r= 0.79, p< 0.001) and a negative correlation between mean blood pressure and the difference between TcCO2 and PaCO2 (r= -0.54, p= 0.001). Multiple regression analysis results showed that lactate level was independently associated with increased differences between TcCO2 and PaCO2 (Beta= 0.875, p< 0.001).

CONCLUSIONS

TcCO2 monitoring may not be reliable in patients with increased lactate levels. TcCO2 levels should be checked by ABG analysis in these patients.

Для цитирования: Gürün Kaya Aslıhan, Özpinar Şeyda Nur, Öz Miraç, Erol Serhat, Arslan Fatma, Çiledağ Aydın, Kaya Akın. The relation of lactate level and carbon dioxide pressure discrepancies between transcutaneous and arterial measurements.. Tuberkuloz ve toraks. 2024. DOI: 10.5578/tt.202402920.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.