m+Medelevator.RU
← Поиск публикаций
Canadian journal of ophthalmology. Journal canadien d'ophtalmologie · 2025

Quantifying the repeatability and reproducibility of Dr. Noon CVD, AI software as medical device for cardiovascular risk assessment via retinal imaging.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hong Rim Kyung, Kim Moonsu, Hong Eun Hee, Kang Min Ho, Shin Yong Un, Park Hwan-Cheol, Hwang Sunjin

Аннотация

OBJECTIVE: To evaluate the repeatability and reproducibility of the Dr.Noon CVD, an artificial intelligence software as a medical device that assesses cardiovascular risk from retinal photographs by providing risk scores and classifying patients into three categories: category 0 (low risk), category 1 (intermediate risk), and category 2 (high risk).

METHODS: In this prospective, single-center study, participants underwent nonmydriatic fundus photography. For repeatability assessment, one examiner captured 3 consecutive images per eye. For reproducibility, a second examiner independently acquired 1 image per eye. Intraclass correlation coefficients (ICCs), within-subject standard deviations, and coefficients of variation were calculated. Differences by risk category and lens status were assessed using ANOVA and independent t tests.

RESULTS: Overall, Dr.Noon CVD demonstrated excellent reliability, with a repeatability ICC of 0.997 (95% confidence interval [CI]: 0.996-0.998) and a reproducibility ICC of 0.999 (95% CI: 0.998-0.999). When analyzed by risk categories, repeatability, and reproducibility ICCs were 0.985 (95% CI: 0.974-0.997) and 0.995 (95% CI: 0.990-0.997) for category 0, 0.960 (95% CI: 0.918-0.983) and 0.969 (95% CI: 0.921-0.988) for category 1, and 0.965 (95% CI: 0.943-0.980) and 0.984 (95% CI: 0.971-0.992) for category 2. In terms of lens status, phakic eyes showed repeatability and reproducibility ICCs of 0.998 (95% CI: 0.996-0.998) and 0.999 (95% CI: 0.998-0.999), respectively, while pseudophakic eyes showed slightly lower but still excellent values of 0.989 (95% CI: 0.980-0.995) and 0.994 (95% CI: 0.988-0.997).

CONCLUSIONS: Dr.Noon CVD demonstrated high precision with excellent repeatability and reproducibility across all risk levels and lens statuses, supporting its reliability for cardiovascular risk screening using retinal images.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты