MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2018.09.029

Медицинская библиотека · International journal of cardiology · 2018

Optimizing flecainide plasma concentration profile for atrial fibrillation conversion while minimizing adverse ventricular effects by rapid, low-dose intratracheal or intravenous administration.

Marum Alexandre A, Silva Bruna A, Bortolotto Alexandre L, Silva Anderson C, de Antonio Victor Z, Belardinelli Luiz, Verrier Richard L

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

We investigated whether rapid administration of a low dose of flecainide, either intratracheally or intravenously (IV), could accelerate conversion of atrial fibrillation (AF) while reducing adverse ventricular effects.

METHODS

Flecainide was delivered via intratracheal administration at 1.5 mg/kg bolus and compared to IV infusion at 1.0 mg/kg over 2 min (lower-dose, rapid) and 2.0 mg/kg over 10 min (ESC guideline) in closed-chest, anesthetized Yorkshire pigs. Catheters were fluoroscopically positioned in right atrium to measure atrial depolarization (Pa) duration and left ventricle (LV) to measure QRS complex duration and contractility (LV dP/dt) during atrial pacing at 140 beats/min. Flecainide was delivered intratracheally via a catheter positioned at the bifurcation of the main bronchi. AF was induced by intrapericardial administration of acetylcholine followed by burst pacing.

RESULTS

Flecainide reduced AF duration similarly by intratracheal and IV delivery. Peak plasma levels were comparable but Tmax differed and coincided with peaks in Pa prolongation. The area under the curve indicating sustained plasma levels was greater for higher-dose, slow IV flecainide than for either intratracheal instillation (by 32%) or lower-dose, rapid IV infusion (by 88%). As a result, higher-dose, slow IV flecainide caused 58% (p < 0.03) and 48% (p < 0.006) greater increases in QRS complex duration and 61% and 96% (both, p < 0.02) greater reductions in contractility compared to intratracheal and lower-dose, rapid IV flecainide, respectively.

CONCLUSION

Lower-dose, rapid flecainide, delivered either intratracheally or IV, optimizes the plasma concentration profile for effective conversion of AF while minimizing adverse effects on QRS complex duration and LV contractility.

Для цитирования: Marum Alexandre A, Silva Bruna A, Bortolotto Alexandre L, Silva Anderson C, de Antonio Victor Z, Belardinelli Luiz, Verrier Richard L. Optimizing flecainide plasma concentration profile for atrial fibrillation conversion while minimizing adverse ventricular effects by rapid, low-dose intratracheal or intravenous administration.. International journal of cardiology. 2018. DOI: 10.1016/j.ijcard.2018.09.029.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.