Critical care (London, England) · 2020
Multiple cross displacement amplification-a more applicable technique in detecting Pseudomonas aeruginosa of ventilator-associated pneumonia (VAP).
СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Wang Juxiang, Chen Huimin, Lin Xiaomin, Ji Chengyi, Chen Bin
Аннотация
BACKGROUND: Early and rapid identification of Pseudomonas aeruginosa (P. aeruginosa) in patients with suspected ventilator-associated pneumonia (VAP) provides theoretical clinical advantages in therapeutic optimization strategies.
METHODS: The P. aeruginosa-multiple cross displacement amplification (PA-MCDA) assay was conducted at an isothermal temperature during the amplification stage, and products were visually detected by color changes. The entire process was completed within 1 h. A total of 77 strains, including P. aeruginosa species and various other species of non-P. aeruginosa, were used to evaluate PA-MCDA assays. Bronchoalveolar lavage fluid (BALF) of suspected VAP patients was examined by the MCDA assay.
RESULTS: The MCDA assay exhibited a 100% analytical specificity in detecting PA from all 77 strains, and the limit of detection was as low as 100 fg DNA per reaction. A temperature of 65 °C was recommended as standard during the amplification stage. The agreement between PA-MCDA and bacteria culture was 91.18% (κ = 0.787; p = 0.000) in the identification of P. aeruginosa in BALF from suspected VAP. The PA-MCDA assay showed values of 92.31%, 90.78%, 77.41%, and 97.18% for sensitivity, specificity, positive predictive value, and negative predictive value, respectively. PA-MCDA had a higher detective rate of P. aeruginosa than bacteria culture in patients with antipseudomonal therapy.
CONCLUSIONS: The instrument-free platform of the MCDA assay makes it a simple, rapid, and applicable procedure for "on-site" diagnosis and point-of-care testing for the presence of P. aeruginosa without the need for specific bacterial culture.
METHODS: The P. aeruginosa-multiple cross displacement amplification (PA-MCDA) assay was conducted at an isothermal temperature during the amplification stage, and products were visually detected by color changes. The entire process was completed within 1 h. A total of 77 strains, including P. aeruginosa species and various other species of non-P. aeruginosa, were used to evaluate PA-MCDA assays. Bronchoalveolar lavage fluid (BALF) of suspected VAP patients was examined by the MCDA assay.
RESULTS: The MCDA assay exhibited a 100% analytical specificity in detecting PA from all 77 strains, and the limit of detection was as low as 100 fg DNA per reaction. A temperature of 65 °C was recommended as standard during the amplification stage. The agreement between PA-MCDA and bacteria culture was 91.18% (κ = 0.787; p = 0.000) in the identification of P. aeruginosa in BALF from suspected VAP. The PA-MCDA assay showed values of 92.31%, 90.78%, 77.41%, and 97.18% for sensitivity, specificity, positive predictive value, and negative predictive value, respectively. PA-MCDA had a higher detective rate of P. aeruginosa than bacteria culture in patients with antipseudomonal therapy.
CONCLUSIONS: The instrument-free platform of the MCDA assay makes it a simple, rapid, and applicable procedure for "on-site" diagnosis and point-of-care testing for the presence of P. aeruginosa without the need for specific bacterial culture.