DOI 10.1080/01676830802414830

Медицинская библиотека · Orbit (Amsterdam, Netherlands) · 2009

A new modification in the porous polyethylene-coated lester jones tube.

Abdulhafez Mohammad, Elgazayerli Erfan, Mansour Tamer, Khalaf Mohammad Anwar

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Conjunctivodacryocystorhinostomy (CDCR) is the gold standard for the treatment of many cases of canalicular obstruction since 1965 (Kominek & Cervenka, 2004). With a proper CDCR and a well-placed Jones tube, the success rate in our experience is almost 100%. The most frequent complication is extrusion and dislocation. Rates as high as 49% have been reported in some studies (Rose & Welham, 1991). Various modifications have been introduced in the tube design in order to minimize extrusion, including tubes with suture holes, the frosted Jones tubes, and regular porous polyethylene-coated tubes. The regular porous polyethylene-coated tubes are covered by a long sleeve of porous polyethylene, which irritates the conjunctiva causing discharge and sometimes granuloma formation. We describe here a modification of this tube with a much shorter porous polyethylene sleeve to minimize the ocular irritation and discharge.

METHODS

Ten patients, age 29-50 years, with complete canalicular obstruction and excessive tearing after failed DCR with canaliculoplasty were included in this study. All patients underwent CDCR with anastomoses of the sac mucosa with that of the nasal mucosa via posterior and anterior flaps. Subsequent placement of porous polyethylene-coated Lester Jones tubes were done at the site of carunculectomy. The regular porous polyethylene coat was shortened using a surgical blade to correspond to the fistula opening, only without extension to the caruncle. The average length of the coat in the 10 cases was about 5 mm.

RESULTS

Postoperatively, all patients had surgically successful outcomes, with no complaints of epiphora or discomfort. All tubes are still in proper position and functioning well. Our follow-up has been limited to an 18-month period.

CONCLUSION

CDCR with the modified porous polyethylene-coated Lester Jones tube has the same advantages of the traditional porous polyethylene-coated tube. Moreover, it reduces the discharge and ocular irritation, which are the main complications of the CDCR with the current porous polyethylene-coated Jones tube.

Для цитирования: Abdulhafez Mohammad, Elgazayerli Erfan, Mansour Tamer, Khalaf Mohammad Anwar. A new modification in the porous polyethylene-coated lester jones tube.. Orbit (Amsterdam, Netherlands). 2009. DOI: 10.1080/01676830802414830.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.