Analysis of Biomechanical Response After Corneal Crosslinking with Different Fluence Levels in Porcine Corneas.

Fischinger Isaak, Reifeltshammer Sophia A, Seiler Theo G, Nambiar Malavika H, Komninou Maria A, Büchler Philippe, Wendelstein Jascha, Langenbucher Achim, Bolz Matthias

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate corneal stiffening of porcine corneas induced by corneal crosslinking (CXL) with constant irradiance as a function of total fluence.

METHODS

Ninety corneas from freshly enucleated porcine eyes were divided into five groups of 18 eyes. Groups 1-4 underwent epi-off CXL using a dextran-based riboflavin solution and an irradiance of 18 mW/cm2, group 5 served as the control group. Groups 1 to 4 were treated with a total fluence of 20, 15, 10.8, and 5.4 J/cm2, respectively. Thereafter, biomechanical measurements were performed on 5 mm wide and 6 mm long strips using an uniaxial material tester. Pachymetry measurements were performed on each cornea.

RESULTS

At 10% strain, the stress was 76, 56, 52, and 31% higher in groups 1-4, respectively compared to the control group. The Young's modulus was 2.85 MPa for group 1, 2.53 MPa for group 2, 2.46 MPa for group 3, 2.12 MPa for group 4, and 1.62 MPa for the control group. The difference between groups 1 to 4 and the control group 5 were statistically significant (p = <0.001; p = <0.001; p = <0.001; p = 0.021). In addition, group 1 showed significantly more stiffening than group 4 (p = <0.001), no other significant differences were found. Pachymetry measurements revealed no statistically significant differences among the five groups.

CONCLUSION

Additional mechanical stiffening can be achieved by increasing the fluence of the CXL. There was no threshold detected up to 20 J/cm2. A higher fluence could compensate the weaker effect of accelerated or epi-on CXL procedures.

Для цитирования: Fischinger Isaak, Reifeltshammer Sophia A, Seiler Theo G, Nambiar Malavika H, Komninou Maria A, Büchler Philippe, Wendelstein Jascha, Langenbucher Achim, Bolz Matthias. Analysis of Biomechanical Response After Corneal Crosslinking with Different Fluence Levels in Porcine Corneas.. Current eye research. 2023. DOI: 10.1080/02713683.2023.2205612.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.