m+Medelevator.RU
← Поиск публикаций
Cornea · 2023

High Astigmatism After Conventional Diameter Deep Anterior Lamellar Keratoplasty in Keratoconus Can Be Successfully Managed With Repeat Wide Diameter Deep Anterior Lamellar Keratoplasty.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Panthagani Jesse, Law Elizabeth M, Chipeta Chimwemwe, Roberts Harry, Myerscough James

Аннотация

PURPOSE: The aim of this study was to describe a new surgical technique to replace a conventional diameter (≤8 mm) deep anterior lamellar keratoplasty (DALK) graft with associated high astigmatism refractory to corneal-based astigmatic procedure/intolerance to contact lenses with a larger diameter (≥9 mm) DALK graft to improve best spectacle-corrected visual acuity (BSCVA).

METHODS: Two eyes from 2 keratoconic patients at Southend University Hospital between December 2019 and June 2021 with a minimum follow-up of 17 months were evaluated. The primary outcome of interest was Snellen BSCVA with a secondary outcome of topographic cylinder.

RESULTS: Patient 1 had undergone initial 8 mm diameter DALK, with residual keratometric astigmatism of nearly 12 diopters (D) postoperatively despite numerous astigmatic interventions, with a BSCVA of 6/60, before undergoing 9 mm diameter repeat modified DALK. After suture removal and subsequent in-the-wound blunt manual relaxing incisions, the patient had a final keratometric astigmatism of 3.5 D, manifest refraction of plano/-3.50 × 175, and a BSCVA of 6/9. Patient 2 had undergone initial 7.75 mm diameter DALK, with residual keratometric astigmatism of 10.5 D with a BSCVA of counting fingers. The patient underwent 9 mm repeat modified DALK with final residual keratometric astigmatism of 3.1 D after suture removal, manifest refraction of -1.00/-2.75 × 25, and BSCVA of 6/9.

CONCLUSIONS: Wide diameter DALK (>9 mm) is effective in the management of conventional diameter DALK (≤8 mm) associated high astigmatism in keratoconus. Creation of a peripheral posterior stromal shoulder also allows safe further titration of residual astigmatism if needed.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты