MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ico.0000000000003298

Медицинская библиотека · Cornea · 2023

High Astigmatism After Conventional Diameter Deep Anterior Lamellar Keratoplasty in Keratoconus Can Be Successfully Managed With Repeat Wide Diameter Deep Anterior Lamellar Keratoplasty.

Panthagani Jesse, Law Elizabeth M, Chipeta Chimwemwe, Roberts Harry, Myerscough James

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to describe a new surgical technique to replace a conventional diameter (≤8 mm) deep anterior lamellar keratoplasty (DALK) graft with associated high astigmatism refractory to corneal-based astigmatic procedure/intolerance to contact lenses with a larger diameter (≥9 mm) DALK graft to improve best spectacle-corrected visual acuity (BSCVA).

METHODS

Two eyes from 2 keratoconic patients at Southend University Hospital between December 2019 and June 2021 with a minimum follow-up of 17 months were evaluated. The primary outcome of interest was Snellen BSCVA with a secondary outcome of topographic cylinder.

RESULTS

Patient 1 had undergone initial 8 mm diameter DALK, with residual keratometric astigmatism of nearly 12 diopters (D) postoperatively despite numerous astigmatic interventions, with a BSCVA of 6/60, before undergoing 9 mm diameter repeat modified DALK. After suture removal and subsequent in-the-wound blunt manual relaxing incisions, the patient had a final keratometric astigmatism of 3.5 D, manifest refraction of plano/-3.50 × 175, and a BSCVA of 6/9. Patient 2 had undergone initial 7.75 mm diameter DALK, with residual keratometric astigmatism of 10.5 D with a BSCVA of counting fingers. The patient underwent 9 mm repeat modified DALK with final residual keratometric astigmatism of 3.1 D after suture removal, manifest refraction of -1.00/-2.75 × 25, and BSCVA of 6/9.

CONCLUSIONS

Wide diameter DALK (>9 mm) is effective in the management of conventional diameter DALK (≤8 mm) associated high astigmatism in keratoconus. Creation of a peripheral posterior stromal shoulder also allows safe further titration of residual astigmatism if needed.

Для цитирования: Panthagani Jesse, Law Elizabeth M, Chipeta Chimwemwe, Roberts Harry, Myerscough James. High Astigmatism After Conventional Diameter Deep Anterior Lamellar Keratoplasty in Keratoconus Can Be Successfully Managed With Repeat Wide Diameter Deep Anterior Lamellar Keratoplasty.. Cornea. 2023. DOI: 10.1097/ico.0000000000003298.

Предметные рубрики MeSH