MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajo.2023.04.002

Медицинская библиотека · American journal of ophthalmology · 2023

Detection of Keratoconus With a New Corvis Biomechanical Index Optimized for Chinese Populations.

Vinciguerra Riccardo, Ambrosio Renato, Wang Yan, Zhang Fengju, Zhou Xingtao, Bai Ji, Yu Keming, Chen Shihao, Fang Xuejun, Vinciguerra Paolo

Многоцентровое исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: The aim of this study was to introduce an optimized version of the Corvis Biomechanical Index for Chinese populations (cCBI).

DESIGN

Retrospective, multicenter clinical validity enhancement study.

METHODS

Patients were included from 7 clinics in Beijing, Shenyang, Guangzhou, Shanghai, Wenzhou, Chongqing, and Tianjin, China. Logistic regression was used to optimize the values of the constants of the CBI, based on database 1 as the development dataset (6 of 7 clinics), to create a new version of the index named cCBI. The factors of the CBI (A1Velocity, ARTh, Stiffness Parameter-A, DARatio2mm, and Inverse Integrated Radius) and the cutoff value were kept the same (0.5). With the formation of cCBI determined, it was validated on database 2 (1 of the 7 clinics).

RESULTS

Two thousand four hundred seventy-three patients (healthy and keratoconus) were included. In database 2, the area under the curve of the cCBI was 0.985 with 93.4% specificity and 95.5% sensitivity. In the same dataset, the original CBI produced an area under the curve of 0.978 with 68.1% specificity and 97.7% sensitivity. There was a statistically significant difference between the receiver operating characteristic curve of cCBI and CBI (De Long P = .0009)

CONCLUSION

The new cCBI for Chinese patients was shown to be statistically significantly better when compared with CBI to separate healthy from keratoconic eyes. The presence of an external validation dataset confirms this finding and suggests the use of cCBI in everyday clinical practice to aid in the diagnosis of keratoconus in patients who are of Chinese ethnicity.

Для цитирования: Vinciguerra Riccardo, Ambrosio Renato, Wang Yan, Zhang Fengju, Zhou Xingtao, Bai Ji, Yu Keming, Chen Shihao, Fang Xuejun, Vinciguerra Paolo. Detection of Keratoconus With a New Corvis Biomechanical Index Optimized for Chinese Populations.. American journal of ophthalmology. 2023. DOI: 10.1016/j.ajo.2023.04.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.