MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1136/bjo-2022-322859

Медицинская библиотека · The British journal of ophthalmology · 2024

Characterisation of ectasia after penetrating keratoplasty in keratoconus eyes using anterior segment optical coherence tomography.

Weller Julia M, Hübner Lisa, Kruse Friedrich E, Tourtas Theofilos

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Ectasia of the cornea can occur decades after penetrating keratoplasty (PK), especially in keratoconus eyes. The purpose of this study was to characterise ectasia after PK by morphological findings in anterior segment optical coherence tomography (AS-OCT).

METHODS

In this retrospective, single-centre case series, 50 eyes of 32 patients with a history of PK at an average of 25±10 years earlier were included. The eyes were classified either as ectatic (n=35) or as non-ectatic (n=15). The main parameters included central corneal thickness (CCT), lowest corneal thickness at the interface (LCTI), anterior chamber depth, graft-host interface angle at the thinnest point and host cornea-iris angle. Furthermore, steep and flat keratometry readings obtained by AS-OCT (CASIA-2, Tomey) and Scheimpflug tomography (Pentacam, Oculus) were assessed. OCT findings were correlated with clinical grading of ectasia.

RESULTS

There was a highly significant difference in LCTI, graft-host interface angle and anterior chamber depth (in pseudophakic eyes) between the groups. The ratio calculated by the quotient of LCTI divided by CCT was significantly lower in ectatic than non-ectatic eyes (p<0.001). In eyes with an LCTI/CCT ratio of ≤0.7, the OR for the occurrence of a clinical detectable ectasia was 2.4 (CI 1.5 to 3.7). Steep keratometry values were significantly higher in ectatic eyes.

CONCLUSION

AS-OCT is a helpful tool to recognise and quantify ectasia in post-PK eyes objectively.

Для цитирования: Weller Julia M, Hübner Lisa, Kruse Friedrich E, Tourtas Theofilos. Characterisation of ectasia after penetrating keratoplasty in keratoconus eyes using anterior segment optical coherence tomography.. The British journal of ophthalmology. 2024. DOI: 10.1136/bjo-2022-322859.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.