Erosion of IPP components into bladder lumen and prostatic urethra.

Bloch Aaron, Buchanan Logan, Cox Lucille, Houle Katherine, Gopal Nikhil, Patterson Anthony, Wake Robert

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

The incidence of erosion of inflatable penile prosthesis (IPP) components into adjacent organs is low (<0.1 %). During a transurethral resection of the prostate (TURP) in a patient with prior IPP placement, we encountered IPP tubing that had eroded into the prostate. The pump and cylinders were later explanted through a penoscrotal approach, with the reservoir drained and retained with plan for follow up cystoscopy in 4-6 weeks. Cystoscopy 1 month later demonstrated reservoir erosion into the bladder lumen. An open cystotomy was performed to retrieve the reservoir. This is the first reported case of IPP tubing eroding into the prostate.

Для цитирования: Bloch Aaron, Buchanan Logan, Cox Lucille, Houle Katherine, Gopal Nikhil, Patterson Anthony, Wake Robert. Erosion of IPP components into bladder lumen and prostatic urethra.. Urology case reports. 2024. DOI: 10.1016/j.eucr.2024.102773.